<P align="center"> '''Teltocharge tethered with Type 1 cable'''
 +
 
[[File:TetheredVersion facade view.png|center|frameless|356x356px|Picture of Tethered version charger]]
 
[[File:TetheredVersion facade view.png|center|frameless|356x356px|Picture of Tethered version charger]]
   −
{| class="wikitable"
+
{| class="wikitable" style="margin: 0px auto;" align="center" table > </table>
 +
 
 
|'''Dimensions without cable'''
 
|'''Dimensions without cable'''
 
|170x341x97 mm
 
|170x341x97 mm
Line 10: Line 14:  
|-
 
|-
 
|'''Operating temperature'''
 
|'''Operating temperature'''
|<nowiki>-30°C - +50°C</nowiki>
+
|<nowiki>   -30°C - +50°C</nowiki>
 
|-
 
|-
 
|'''IP rating'''
 
|'''IP rating'''
|IP55
+
| IP55
 
|-
 
|-
 
|'''IK rating'''
 
|'''IK rating'''
Line 25: Line 29:  
|}
 
|}
    +
==Electrical specifications==
    +
Here you can find information about electric parameters of Teltocharge product
   −
==Site preparation requirements==
+
{| class="wikitable" style="margin: 0px auto;" align="center" table > </table>
 +
! colspan="4" |AC INPUT SPECIFICATIONS
 +
|-
 +
|Maximum power
 +
|7,6 kW
 +
|9,6 kW
 +
|11,5 kW
 +
|-
 +
|Input AC power connection
 +
| colspan="3" |2 phases
 +
|-
 +
|Maximum current
 +
|32 A
 +
|40 A
 +
|48 A
 +
|-
 +
|Input voltage
 +
| colspan="3" |2 phases: (L-L) 240 ± 10% VAC
 +
|-
 +
|Rated frequency
 +
| colspan="3" |50 / 60 HZ
 +
|-
 +
| Standby power consumption
 +
| colspan="3" |4 W
 +
|-
 +
| Earth (ground) fault protection
 +
| colspan="3" |20 mA AC, 6 mA DC
 +
|-
 +
|Overvoltage category
 +
| colspan="3" |OVC II
 +
|-
 +
|Protection against electric shock
 +
| colspan="3" |Class I
 +
|-
 +
! colspan="4" |AC Output specifications
 +
|-
 +
|AC output voltage range
 +
| colspan="3" |1 phase: (L-N) 240 ± 10% VAC
 +
|-
 +
|Connection Standart
 +
| colspan="3" |Type 1 cable
 +
|-
 +
|Connection to the grid
 +
| colspan="2" |NEMA 6-50 plug to the wall socket
 +
|Direct cable from house grid
 +
(Hardwired)
 +
|-
 +
! colspan="4" |'''Power Cable'''
 +
|-
 +
|Maximum cable diameter
 +
|17.5 mm
 +
|
 +
| 20,75 mm
 +
|-
 +
|Maximum wire cross section
 +
| 7.5 mm<sup>2</sup>
 +
|
 +
|
 +
|}
 +
==Site preparation requirements ==
 
*Find a suitable site on a wall (The mounting surface required to be flat and stable, for example a finished, brick or concrete wall. Wall required to be suitable to withstand TeltoCharge weight with charging cable)​.
 
*Find a suitable site on a wall (The mounting surface required to be flat and stable, for example a finished, brick or concrete wall. Wall required to be suitable to withstand TeltoCharge weight with charging cable)​.
*Make sure that the required power supply is easily accessible. (Required power supply depends on the type of charger).
+
* Make sure that the required power supply is easily accessible. (Required power supply depends on the type of charger).
 
*Recommendation is not to install TeltoCharge on direct sunlight to avoid overheating.
 
*Recommendation is not to install TeltoCharge on direct sunlight to avoid overheating.
 
==Installation process==
 