Changes

no edit summary
Line 38: Line 38:  
| style="padding: 8px;" | 10 %
 
| style="padding: 8px;" | 10 %
 
| style="padding: 8px;" | [[Lower voltage tolerance]]
 
| style="padding: 8px;" | [[Lower voltage tolerance]]
   
|-
 
|-
 
| style="padding: 8px;" | 05
 
| style="padding: 8px;" | 05
 +
| style="padding: 8px;" | '''Three phase charging'''
 +
| style="padding: 8px;" | OFF
 +
| style="padding: 8px;" | [[Three phase charging]]
 +
|-
 +
| style="padding: 8px;" | 06
 
| style="padding: 8px;" | '''Phase priority'''
 
| style="padding: 8px;" | '''Phase priority'''
 
| style="padding: 8px;" | L1
 
| style="padding: 8px;" | L1
 
| style="padding: 8px;" | [[Phase priority]]
 
| style="padding: 8px;" | [[Phase priority]]
 
|-
 
|-
| style="padding: 8px;" | 06
+
| style="padding: 8px;" | 07
 
| style="padding: 8px;" | '''Difference between phases'''
 
| style="padding: 8px;" | '''Difference between phases'''
 
| style="padding: 8px;" | 120 °
 
| style="padding: 8px;" | 120 °
 
| style="padding: 8px;" | [[Difference between phases]]
 
| style="padding: 8px;" | [[Difference between phases]]
 
|-
 
|-
| style="padding: 8px;" | 07
+
| style="padding: 8px;" | 08
 
| style="padding: 8px;" | '''Use neutral as phase'''
 
| style="padding: 8px;" | '''Use neutral as phase'''
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | [[Use neutral as phase]]
 
| style="padding: 8px;" | [[Use neutral as phase]]
 
|-
 
|-
| style="padding: 8px;" | 08
+
| style="padding: 8px;" | 09
 
| style="padding: 8px;" | '''Use data from energy meter'''
 
| style="padding: 8px;" | '''Use data from energy meter'''
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | [[Use data from energy meter]]
 
| style="padding: 8px;" | [[Use data from energy meter]]
 
|-
 
|-
| style="padding: 8px;" | 09
+
| style="padding: 8px;" | 10
 
| style="padding: 8px;" | '''kWh meter address'''
 
| style="padding: 8px;" | '''kWh meter address'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - follow link on the right.''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - follow link on the right.''
 
| style="padding: 8px;" rowspan="5" | [https://wiki.teltonika-energy.com/view/Smart_energy_meters#TeltoCharge_supported_smart_energy_meters Choose your Smart energy meter and its parameters]
 
| style="padding: 8px;" rowspan="5" | [https://wiki.teltonika-energy.com/view/Smart_energy_meters#TeltoCharge_supported_smart_energy_meters Choose your Smart energy meter and its parameters]
 
|-
 
|-
| style="padding: 8px;" | 10
+
| style="padding: 8px;" | 11
 
| style="padding: 8px;" | '''Energy meter type'''
 
| style="padding: 8px;" | '''Energy meter type'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
|-
 
|-
|-
+
| style="padding: 8px;" | 12
| style="padding: 8px;" | 11
   
| style="padding: 8px;" | '''RS-485 baudrate'''
 
| style="padding: 8px;" | '''RS-485 baudrate'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
|-
 
|-
| style="padding: 8px;" | 12
+
| style="padding: 8px;" | 13
 
| style="padding: 8px;" | '''RS-485 parity'''
 
| style="padding: 8px;" | '''RS-485 parity'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
|-
 
|-
| style="padding: 8px;" | 13
+
| style="padding: 8px;" | 14
 
| style="padding: 8px;" | '''RS-485 stop bit'''
 
| style="padding: 8px;" | '''RS-485 stop bit'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
|-
 
|-
| style="padding: 8px;" | 14
+
| style="padding: 8px;" | 15
 
| style="padding: 8px;" | '''Dynamic load balancing'''
 
| style="padding: 8px;" | '''Dynamic load balancing'''
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | [[Dynamic Load Balancing]]
 
| style="padding: 8px;" | [[Dynamic Load Balancing]]
 
|-
 
|-
| style="padding: 8px;" | 15
+
| style="padding: 8px;" | 16
 
| style="padding: 8px;" | '''Use preferred phase'''
 
| style="padding: 8px;" | '''Use preferred phase'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.'''
 
| style="padding: 8px;" | [[Use prefered phase]]
 
| style="padding: 8px;" | [[Use prefered phase]]
 
|-
 
|-
| style="padding: 8px;" | 16
+
| style="padding: 8px;" | 17
 
| style="padding: 8px;" | '''Energy meter address'''
 
| style="padding: 8px;" | '''Energy meter address'''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
| style="padding: 8px;" | '''Not needed to adjust if Dynamic load balancing is OFF.''' <br> ''If it's ON - you must follow link on the right.''
 
| style="padding: 8px;" | [https://wiki.teltonika-energy.com/view/Smart_energy_meters#TeltoCharge_supported_smart_energy_meters Choose your Smart energy meter and its parameters]
 
| style="padding: 8px;" | [https://wiki.teltonika-energy.com/view/Smart_energy_meters#TeltoCharge_supported_smart_energy_meters Choose your Smart energy meter and its parameters]
 
|-
 
|-
| style="padding: 8px;" | 17
+
| style="padding: 8px;" | 18
 
| style="padding: 8px;" | '''Allow simplified charging sequence'''
 
| style="padding: 8px;" | '''Allow simplified charging sequence'''
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | OFF
 
| style="padding: 8px;" | [[Allow simplified charging sequence]]
 
| style="padding: 8px;" | [[Allow simplified charging sequence]]
 
|-
 
|-
| style="padding: 8px;" | 18
+
| style="padding: 8px;" | 19
 
| style="padding: 8px;" | '''Charger location is ventilated'''
 
| style="padding: 8px;" | '''Charger location is ventilated'''
 
| style="padding: 8px;" | OFF (if your TeltoCharge is inside the property)
 
| style="padding: 8px;" | OFF (if your TeltoCharge is inside the property)
 
| style="padding: 8px;" | [[Charger location is ventilated]]
 
| style="padding: 8px;" | [[Charger location is ventilated]]
 
|-
 
|-
| style="padding: 8px;" | 19
+
| style="padding: 8px;" | 20
 
| style="padding: 8px;" | '''Temperature warning'''
 
| style="padding: 8px;" | '''Temperature warning'''
 
| style="padding: 8px;" | 60 °C
 
| style="padding: 8px;" | 60 °C

Navigation menu