Changes

Created page with "=General specifications= A specification often refers to a set of documented requirements to be satisfied by a material, design, product, or service. A specification is often..."
=General specifications=
A specification often refers to a set of documented requirements to be satisfied by a material, design, product, or service. A specification is often a type of technical standard.
<br>
{| class="wikitable" style="text-align: center;"
| Dimensions without cable || 170x341x97 mm
|-
| Weight without cable || 2,8 kg
|-
| Operating temperature || -30°C - +50°C
|-
| IP rating || IP55
|-
| IK rating || IK10
|-
| Certification || CE
|-
| Standards || 2014/35/EU, 2014/30/EU
IEC 61851-1, IEC 61851-22
|}

=Electrical specifications=
TeltoCharge have different configurations, which can be customizable to suit user needs.
&rarr; [[First start of 7.4 kW charger]]</li> <br>
&rarr; [[First start of 11 kW charger]]</li> <br>
&rarr; [[First start of 22 kW charger]]</li>

{| class="wikitable" style="text-align: center;"
! colspan="4" |AC INPUT SPECIFICATIONS
|-
|
|7,4 kW
|11 kW
|22 kW
|-
|Input AC power connection
|1 phase
|1 or 3 phases
|1 or 3 phases
|-
|Maximum current
|32 A
|16 A
|32 A
|-
| rowspan="2" |Input voltage
| rowspan="2" |(L-N) 230 ± 10% VAC
| colspan="2" |3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC
|-
| colspan="2" |1 phase: (L-N) 230 ± 10% VAC
|-
|Rated frequency
| colspan="3" |50 / 60 HZ
|-
|Standby power consumption
| colspan="3" |4 W
|-
|Earth (ground) fault protection
| colspan="3" |30 mA AC, 6 mA DC
|-
|Overvoltage category
| colspan="3" |CAT III
|-
|Protection against electric shock
| colspan="3" |Class I
|-
! colspan="4" |AC Output specifications
|-
| rowspan="2" |AC output voltage range
| rowspan="2" |(L-N) 230 ± 10% VAC
| colspan="2" |3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC
|-
| colspan="2" |1 phase: (L-N) 230 ± 10% VAC
|-
|Connection Standart
| colspan="3" |Type 2 cable
Type 2 socket
|-
! colspan="4" |'''Power Cable'''
|-
|Maximum cable diameter
| colspan="3" |17.5 mm
|-
|Maximum wire cross section
| colspan="3" |7.5 mm<sup>2</sup>
|}