Jump to content

Electrical Specifications EVC2

From Teltonika Energy Wiki
Main Page > TeltoCharge > General information > Electrical Specifications EVC2

EVC2 Eletrical Speficications

EVC2 have different product configurations, which can be customizable to suit user needs.

AC INPUT SPECIFICATIONS
EVC20X0 7,4 kW EVC20X1 11 kW EVC20X2 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Maximum current per phase 32 A 16 A 32 A
Max power on single phase 7.4 kW 3.7 kW 7.4 kW
Max power on three phase N/A 11 kW 22 kW
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 3 W
RCD-DD 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

T2S socket

Power Cable
Maximum cable diameter 25 mm
Maximum wire cross section 10 mm2