Difference between revisions of "Dynamic Load Balancing"

From Wiki
 
(4 intermediate revisions by the same user not shown)
Line 20: Line 20:
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Technical information
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Technical information
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Configuration in mobile application
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Configuration in mobile application
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Wiring scheme
  
 
|-
 
|-
Line 25: Line 26:
 
| style="padding: 2px;" | [[EM and ET models]] <br>
 
| style="padding: 2px;" | [[EM and ET models]] <br>
 
| style="padding: 2px;" | [[Carlo Gavazzi settings]]
 
| style="padding: 2px;" | [[Carlo Gavazzi settings]]
 +
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/view/EM_and_ET_models#Carlo_Gavazzi_meters_wiring: METER -> TELTOCHARGE] <br>
  
 
|-
 
|-
Line 30: Line 32:
 
| style="padding: 2px;" | [[PAC models]] <br>
 
| style="padding: 2px;" | [[PAC models]] <br>
 
| style="padding: 2px;" | [[Siemens settings]]
 
| style="padding: 2px;" | [[Siemens settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
  
 
|-
 
|-
Line 35: Line 38:
 
| style="padding: 2px;" | [[A and B models]] <br>
 
| style="padding: 2px;" | [[A and B models]] <br>
 
| style="padding: 2px;" | [[ABB settings]]
 
| style="padding: 2px;" | [[ABB settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
  
 
|-
 
|-
 
| style="padding: 2px;" | Eastron SDMxx <br>
 
| style="padding: 2px;" | Eastron SDMxx <br>
| style="padding: 2px;" | [[SMD models]] <br>
+
| style="padding: 2px;" | [[SDM models]] <br>
 
| style="padding: 2px;" | [[Eastron settings]]
 
| style="padding: 2px;" | [[Eastron settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
  
 
|-
 
|-
Line 45: Line 50:
 
| style="padding: 2px;" | [[PRO model]]  
 
| style="padding: 2px;" | [[PRO model]]  
 
| style="padding: 2px;" | [[Inepro settings]]
 
| style="padding: 2px;" | [[Inepro settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
  
 
|-
 
|-
| style="padding: 8px;" colspan="4" | ''More coming soon...''
 
  
|}
+
| style="padding: 2px;" | Chint <br>
 +
| style="padding: 2px;" | [[Chint models]]
 +
| style="padding: 2px;" | [[Chint settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
  
== Carlo Gavazzi meters wiring: ==
+
|-
  
''Note: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.  ''
+
| style="padding: 2px;" | Entes <br>
 +
| style="padding: 2px;" | [[ES models]]
 +
| style="padding: 2px;" | [[Entes settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
|-
 +
| style="padding: 2px;" | Acrel <br>
 +
| style="padding: 2px;" | [[Acrel models]]
 +
| style="padding: 2px;" | [[Acrel settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
|-
  
===== 1st series to TeltoCharge connection =====
+
| style="padding: 8px;" colspan="4" | ''More coming soon...''
[[File:TeltoCharge DLB CarloGavazzi 1phase.png|center|frameless|524x524px]]
+
|-
  
===== 3rd and 5th series to TeltoCharge connection =====
 
[[File:TeltoCharge DLB CarloGavazzi 3phase.png|center|frameless|521x521px]]
 
  
  
==== Powering the energy meter ====
+
|}
To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.
 
 
 
  
[[Category: TeltoCharge]]
+
[[Category: Advanced Topics]]

Latest revision as of 15:34, 24 November 2023

Main Page > TeltoCharge > Advanced Topics > Dynamic Load Balancing

DYNAMIC LOAD BALANCING

TeltoCharge have the ability to communicate with dedicated smart energy meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet user habits. Smart energy meter should always be installed in source electrical cabinet as showed below.  

Smart meter and TeltoCharge communication

Smart meter and TeltoCharge communicates via Modbus RS-485 protocol. In order to achieve smooth communication, it is recommended to use communication cable according to this protocol. Check example below

TeltoCharge DLB CableExample.png

Note: Communication cable should be integrated with power cable.

Supported energy meters

In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided below.  

TeltoCharge supported smart energy meters

Energy meter manufacturer Technical information Configuration in mobile application Wiring scheme
Carlo Gavazzi series 1-3
EM and ET models
Carlo Gavazzi settings METER -> TELTOCHARGE
Siemens PACxxxx
PAC models
Siemens settings METER -> TELTOCHARGE
ABB A4x ; B2x
A and B models
ABB settings METER -> TELTOCHARGE
Eastron SDMxx
SDM models
Eastron settings METER -> TELTOCHARGE
Inepro PRO380
PRO model Inepro settings METER -> TELTOCHARGE
Chint
Chint models Chint settings METER -> TELTOCHARGE
Entes
ES models Entes settings METER -> TELTOCHARGE
Acrel
Acrel models Acrel settings METER -> TELTOCHARGE
More coming soon...