=EVC2 Electrical Specifications=
=EVC2 Eletrical Speficications=
This section provides detailed information on the electrical specifications and compliance standards for the EVC2 charger.
 
<br>
EVC2 have different product configurations, which can be customizable to suit user needs.  
{| class="wikitable" style="text-align: center; border: 1px solid #414042; font-family: arial, sans-serif; width: 100%;"
 
! style="background-color: #0054A6; color: #FFFFFF; padding: 8px; font-size: 25px;" | Electrical Specifications
{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 60%;"
! style="background-color: #0054A6; color: #FFFFFF; padding: 8px; font-size: 25px;" | Details
! colspan="4"; style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |AC INPUT SPECIFICATIONS
|-
|-
| <b>Voltage</b> || <table style="width: 100%; border-collapse: collapse;"><tr><td style="border: none; padding: 5px;"><b>Single phase:</b></td><td style="border: none; padding: 5px;">230V (+10%)</td></tr><tr><td style="border: none; padding: 5px;"><b>Three phase:</b></td><td style="border: none; padding: 5px;">400V (+10%)</td></tr></table>
|
|'''EVC10X 7,4 kW'''
|'''EVC11X 11 kW'''
|'''EVC12X 22 kW'''
|-
|-
| <b>Charging Power</b> || <table style="width: 100%; border-collapse: collapse;"><tr><td style="border: none; padding: 5px;"><b>Single phase:</b></td><td style="border: none; padding: 5px;">Up to 7.4 kW</td></tr><tr><td style="border: none; padding: 5px;"><b>Three phase:</b></td><td style="border: none; padding: 5px;">Up to 22 kW</td></tr></table>
|Input AC power connection
|1 phase
|1 or 3 phases
|1 or 3 phases
|-
|-
| <b>Frequency</b> || 50/60 Hz
|Maximum current
|32 A
|16 A
|32 A
|-
|-
| <b>PEN Protection</b> || Not applicable
|Max power on single phase
|7.4 kW
|3.7 kW
|7.4 kW
|-
|-
| <b>Network Type</b> || T/N; TT
|Max power on three phase
|Not applicable
|11 kW
|22 kW
|-
|-
| <b>Charging Mode</b> || Mode 3 (according to IEC/EN 61851-1)
| rowspan="2" |Input voltage
| rowspan="2" |(L-N) 230 ± 10% VAC
| colspan="2" |3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC
|-
|-
| <b>Internal RCD-DC</b> || 6 mA DC (according to IEC/EN 62955)
| colspan="2" |1 phase: (L-N) 230 ± 10% VAC
|-
|-
| <b>Overvoltage Category</b> || Category III (according to IEC/EN 60664-1)
|Rated frequency
| colspan="3" |50 / 60 HZ
|-
|Standby power consumption
| colspan="3" |4 W
|-
|Earth (ground) fault protection
| colspan="3" |30 mA AC, 6 mA DC
|-
|Overvoltage category
| colspan="3" |CAT II
|-
|Protection against electric shock
| colspan="3" |Class I
|-
! colspan="4" style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |AC Output specifications
|-
| rowspan="2" |AC output voltage range
| rowspan="2" |(L-N) 230 ± 10% VAC
| colspan="2" |3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC
|-
| colspan="2" |1 phase: (L-N) 230 ± 10% VAC
|-
|Connection Standart
| colspan="3" |Type 2 cable
Type 2 socket
|-
! colspan="4" style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |'''Power Cable'''
|-
|Maximum cable diameter
| colspan="3" |17.5 mm
|-
|Maximum wire cross section
| colspan="3" |7.5 mm<sup>2</sup>
|}
|}
[[Category: General information]]

Revision as of 15:42, 21 February 2025

Main Page > TeltoCharge > General information > Electrical Specifications EVC2

EVC2 Eletrical Speficications

EVC2 have different product configurations, which can be customizable to suit user needs.

AC INPUT SPECIFICATIONS
EVC10X 7,4 kW EVC11X 11 kW EVC12X 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Maximum current 32 A 16 A 32 A
Max power on single phase 7.4 kW 3.7 kW 7.4 kW
Max power on three phase Not applicable 11 kW 22 kW
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT II
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

Power Cable
Maximum cable diameter 17.5 mm
Maximum wire cross section 7.5 mm2