Difference between revisions of "Siemens settings"
From Wiki
m (Protected "Siemens settings" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))) |
|||
Line 11: | Line 11: | ||
|- | |- | ||
| style="padding: 8px;" | Baud rate | | style="padding: 8px;" | Baud rate | ||
− | | style="padding: 8px;" | | + | | style="padding: 8px;" | 19200 |
|- | |- | ||
| style="padding: 8px;" | Parity | | style="padding: 8px;" | Parity | ||
Line 18: | Line 18: | ||
|- | |- | ||
| style="padding: 8px;" | Stop bits | | style="padding: 8px;" | Stop bits | ||
− | | style="padding: 8px;" | | + | | style="padding: 8px;" | 2 |
|} | |} |
Revision as of 08:19, 10 March 2023
RS485 parameters for energy meter Siemens PAC1020 ; PAC2200 ; PAC3100 ; PAC3120 ; Siemens PAC3200 ; Siemens PAC3220 ; Siemens PAC4200
Note: Energy meter parameters should match EVSE default parameters.
RS485 parameter | EVSE default parameter value (configurable in mobile app) |
---|---|
Modbus adress | 126 |
Baud rate | 19200 |
Parity | None |
Stop bits | 2 |