Dynamic Load Balancing: Difference between revisions
No edit summary |
No edit summary |
||
| Line 87: | Line 87: | ||
<li>Enable "'''''Load Balancing'''''"</li> | <li>Enable "'''''Load Balancing'''''"</li> | ||
<li>If smart meter is connected with RS485 wires, press "'''''Search For Device'''''"</li> | <li>If smart meter is connected with RS485 wires, press "'''''Search For Device'''''"</li> | ||
<li>*If TeltoCharge is unable to identify energy meter - use "'''''Manual Setup'''''" </li> | <li>*'''ONLY If TeltoCharge is unable''' to identify energy meter - use "'''''Manual Setup'''''" </li> | ||
[[File:DLB settings.png | [[File:DLB settings.png|left|900x900px|frameless]] | ||
</ol> | </ol> | ||
[[Category: Advanced Topics]] | [[Category: Advanced Topics]] | ||
Revision as of 11:07, 19 May 2025
Main Page > TeltoCharge > Advanced Topics > Dynamic Load BalancingDYNAMIC LOAD BALANCING
TeltoCharge have the ability to communicate with dedicated smart energy meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet user habits. Smart energy meter should always be installed in source electrical cabinet as showed below.

Smart meter and TeltoCharge communication
Smart meter and TeltoCharge communicates via Modbus RS-485 protocol. In order to achieve smooth communication, it is recommended to use communication cable according to this protocol. Check example below

Note: Communication cable should be integrated with power cable.
Supported energy meters
In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided below.
TeltoCharge supported smart energy meters
| Energy meter manufacturer | Technical information | Configuration in mobile application | Wiring scheme |
|---|---|---|---|
| Carlo Gavazzi series 1-3 |
EM and ET models |
Carlo Gavazzi settings | METER -> TELTOCHARGE |
| Siemens PACxxxx |
PAC models |
Siemens settings | METER -> TELTOCHARGE |
| ABB A4x ; B2x |
A and B models |
ABB settings | METER -> TELTOCHARGE |
| Eastron SDMxx |
SDM models |
Eastron settings | METER -> TELTOCHARGE |
| Inepro PRO380 |
PRO model | Inepro settings | METER -> TELTOCHARGE |
| Chint |
Chint models | Chint settings | METER -> TELTOCHARGE |
| Entes |
ES models | Entes settings | METER -> TELTOCHARGE |
| Acrel |
Acrel models | Acrel settings | METER -> TELTOCHARGE |
| More coming soon... | |||
LOAD BALANCING APPLICATION SETTINGS
To ensure everything works correctly, please apply the following setup :