Jump to content

Electrical Specifications EVC2: Difference between revisions

From Teltonika Energy Wiki
No edit summary
m KarolisS moved page Electrical SpecificationsEVC2 to Electrical Specifications EVC2 without leaving a redirect: Misspelled title
 
(3 intermediate revisions by 2 users not shown)
Line 7: Line 7:
|-
|-
|
|
|'''EVC10X 7,4 kW'''
|'''EVC20X0 7,4 kW'''
|'''EVC11X 11 kW'''
|'''EVC20X1 11 kW'''
|'''EVC12X 22 kW'''
|'''EVC20X2 22 kW'''
|-
|-
|Input AC power connection
|Input AC power connection
Line 16: Line 16:
|1 or 3 phases
|1 or 3 phases
|-
|-
|Maximum current
|Maximum current per phase
|32 A
|32 A
|16 A
|16 A
Line 23: Line 23:
|Max power on single phase
|Max power on single phase
|7.4 kW
|7.4 kW
|3.7 kW
|'''3.7 kW'''
|7.4 kW
|7.4 kW
|-
|-
|Max power on three phase
|Max power on three phase
|Not applicable
|N/A
|11 kW
|11 kW
|22 kW
|22 kW
Line 42: Line 42:
|-
|-
|Standby power consumption
|Standby power consumption
| colspan="3" |4 W
| colspan="3" |3 W
|-
|-
|Earth (ground) fault protection
|RCD-DD
| colspan="3" |30 mA AC, 6 mA DC
| colspan="3" |6 mA DC
|-
|-
|Overvoltage category
|Overvoltage category
| colspan="3" |CAT II
| colspan="3" |CAT III
|-
|-
|Protection against electric shock
|Protection against electric shock
Line 65: Line 65:
| colspan="3" |Type 2 cable
| colspan="3" |Type 2 cable
Type 2 socket
Type 2 socket
T2S socket
|-
|-
! colspan="4" style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |'''Power Cable'''
! colspan="4" style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |'''Power Cable'''
|-
|-
|Maximum cable diameter
|Maximum cable diameter
| colspan="3" |17.5 mm
| colspan="3" |25 mm
|-
|-
|Maximum wire cross section
|Maximum wire cross section
| colspan="3" |7.5 mm<sup>2</sup>
| colspan="3" |10 mm<sup>2</sup>
|}
|}


[[Category: General information]]
[[Category: General information]]

Latest revision as of 10:49, 21 August 2025

Main Page > TeltoCharge > General information > Electrical Specifications EVC2

EVC2 Eletrical Speficications

EVC2 have different product configurations, which can be customizable to suit user needs.

AC INPUT SPECIFICATIONS
EVC20X0 7,4 kW EVC20X1 11 kW EVC20X2 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Maximum current per phase 32 A 16 A 32 A
Max power on single phase 7.4 kW 3.7 kW 7.4 kW
Max power on three phase N/A 11 kW 22 kW
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 3 W
RCD-DD 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

T2S socket

Power Cable
Maximum cable diameter 25 mm
Maximum wire cross section 10 mm2