Troubleshooting Guide: Difference between revisions
No edit summary |
mNo edit summary |
||
| (7 intermediate revisions by 2 users not shown) | |||
| Line 14: | Line 14: | ||
<ul style="list-style-type: none; margin: 0; padding: 0;"> | <ul style="list-style-type: none; margin: 0; padding: 0;"> | ||
Simple steps to finding a place in your mobile application where you can check your current TeltoCharge firmware version and update it to the latest. Please always check if you have latest firmware version in your charger. | Simple steps to finding a place in your mobile application where you can check your current TeltoCharge firmware version and update it to the latest. Please always check if you have latest firmware version in your charger. | ||
<br>1. Go to Teltonika Energy app settings | <br>1. Go to Teltonika Energy app settings and press '''Device info'''; <br>2. Press '''Check for updates'''; <br>3. At the top, current firmware version can be found. <br> | ||
[[File: | [[File:FW version check.png|center|frameless|700x700px]] | ||
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">How to download troubleshoot file?</h2> | <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">How to download troubleshoot file?</h2> | ||
<ul style="list-style-type: none; margin: 0; padding: 0;"> | <ul style="list-style-type: none; margin: 0; padding: 0;"> | ||
Simple steps of finding place in your mobile application where you can download '''troubleshoot file'''. | Simple steps of finding place in your mobile application where you can download '''troubleshoot file'''. | ||
<br> | <br> | ||
1. Go to | 1. Go to the '''Diagnostics.'''<br> | ||
2. Slide to the bottom. <br> | 2. Slide to the bottom. <br> | ||
3. Click '''Download troubleshoot file'''. <br> | 3. Click '''Troubleshoot file'''. <br> | ||
4 Click '''Download troubleshoot file'''. <br> | |||
5. Wait until '''file downloaded''' message pop-up.<br> | |||
6. Select the downloaded file.<br> | |||
7. '''Click''' At the top right corner and press '''share'''<br> | |||
<br> | |||
'''Note:''' For best results, please download the file '''during charging session.''' Then more details about current situation would be saved. | '''Note:''' For best results, please download the file '''during charging session.''' Then more details about current situation would be saved. | ||
<br> | <br> | ||
[[File: | [[File:Download guide.png|900x900px|center]] | ||
<h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">LED indicators</h2> | <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">LED indicators</h2> | ||
| Line 64: | Line 62: | ||
|White LED‘s rolling from the top to the bottom – shows that TeltoCharge is Reserved (OCPP only) | |White LED‘s rolling from the top to the bottom – shows that TeltoCharge is Reserved (OCPP only) | ||
| White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action | | White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action | ||
| Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings. | |Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings. | ||
|Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required. | |Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required. | ||
|Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C). | |Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C). | ||
| Line 82: | Line 80: | ||
| | | | ||
|Authorize yourself with app or NFC card. | |Authorize yourself with app or NFC card. | ||
| 1. Go to settings via Teltonika energy APP and select schedule time section to check for set graphs<br> | |1. Go to settings via Teltonika energy APP and select schedule time section to check for set graphs<br> | ||
2. Wait for more available power or increase amperage limits via settings (if your grid allows it)<br> | 2. Wait for more available power or increase amperage limits via settings (if your grid allows it)<br> | ||
3. Available power is less than 6 Amperes. Provide more power or wait for more to generate.<br> | 3. Available power is less than 6 Amperes. Provide more power or wait for more to generate.<br> | ||
| Line 110: | Line 108: | ||
|Green LED‘s pulsing - Initialisation of charging. | |Green LED‘s pulsing - Initialisation of charging. | ||
|Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process. | |Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process. | ||
| Green LED‘s on – TeltoCharge finished charging. | |Green LED‘s on – TeltoCharge finished charging. | ||
| Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D). | |Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D). | ||
| Red four middle LED's - NFC/RFID card declined from the server. | |Red four middle LED's - NFC/RFID card declined from the server. | ||
|Green four middle LED's - NFC/RFID card accepted from the server. | | Green four middle LED's - NFC/RFID card accepted from the server. | ||
|- | |- | ||
| | | | ||
| Line 163: | Line 161: | ||
Output current. | Output current. | ||
| Current leakage detected | |Current leakage detected | ||
|Cable lock; | |Cable lock; | ||
PP fail; | PP fail; | ||
| Line 173: | Line 171: | ||
| | | | ||
Problems with energy meter: | Problems with energy meter: | ||
* Unrecognized; | *Unrecognized; | ||
*Badly set; | *Badly set; | ||
*Communication problems; | *Communication problems; | ||
Other problems: | Other problems: | ||
*Temperature; | *Temperature; | ||
* Current ; | *Current ; | ||
*D state. | *D state. | ||
|- | |- | ||
| Line 191: | Line 189: | ||
*Reboot charger and try to connect EV again. | *Reboot charger and try to connect EV again. | ||
| | | | ||
*Disconnect the cable from the EV and check if the error persists. | * Disconnect the cable from the EV and check if the error persists. | ||
*If the error is cleared, try to start charging. If the error occurs once again, try following steps: | *If the error is cleared, try to start charging. If the error occurs once again, try following steps: | ||
* Check if charging cable is fully pluged into socket and/or EV; | *Check if charging cable is fully pluged into socket and/or EV; | ||
*Check if the inside of both the socket and the plug has no foreign materials inside (is clean). | *Check if the inside of both the socket and the plug has no foreign materials inside (is clean). | ||
*Check visually if the cable is not damaged. | * Check visually if the cable is not damaged. | ||
*Check if the boards are not covered in dust and/or other materials. | *Check if the boards are not covered in dust and/or other materials. | ||
| | | | ||
*Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side; | *Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side; | ||
* Try to reconnect charging cable to the EV and EVSE (if it is socket version). | *Try to reconnect charging cable to the EV and EVSE (if it is socket version). | ||
*Listen if you can hear a clicking sound from the TeltoCharge when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager. | *Listen if you can hear a clicking sound from the TeltoCharge when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager. | ||
*If any of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard. | *If any of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard. | ||
| | |||
*Check the temperature inside Teltonika Energy app > Device info. If temperature is higher than 85 ℃ wait while charger cools down. | |||
| | | | ||
*Restart TeltoCharge | *Restart TeltoCharge | ||
| | | | ||
| Line 226: | Line 224: | ||
|- | |- | ||
|Simple CP detected | |Simple CP detected | ||
|Temperature warning | | Temperature warning | ||
|Ventilation required | |Ventilation required | ||
|RTC time lost | |RTC time lost | ||
| Line 232: | Line 230: | ||
|D state denied | |D state denied | ||
|Sensors not calibrated | |Sensors not calibrated | ||
| Energy meter comm error | |Energy meter comm error | ||
|NFC init error | |NFC init error | ||
|Low battery voltage | |Low battery voltage | ||
|Emeter wrong type | |Emeter wrong type | ||
|E-meter unidetified | |E-meter unidetified | ||
|Main Board boot fail | | Main Board boot fail | ||
|- | |- | ||
|- | |- | ||
| Line 247: | Line 245: | ||
is present. | is present. | ||
| EV requiring ventilation | |EV requiring ventilation | ||
|EVSE date and time lost | | EVSE date and time lost | ||
|Simplified CP detected and not allowed | |Simplified CP detected and not allowed | ||
|EV requiring ventilation but charging location is not ventilated | | EV requiring ventilation but charging location is not ventilated | ||
|Sensors were not calibrated during HW configuration | |Sensors were not calibrated during HW configuration | ||
|Energy meter communication error | |Energy meter communication error | ||
|NFC initialization error | |NFC initialization error | ||
|Low battery voltage EVSE (RTC) | |Low battery voltage EVSE (RTC) | ||
| Energy meter configuration mismatch | |Energy meter configuration mismatch | ||
|Energy meter type unidentified | |Energy meter type unidentified | ||
|Main board is failing to boot | |Main board is failing to boot | ||
| Line 282: | Line 280: | ||
| | | | ||
Check EVSE RTC coin battery (CR 1220). | Check EVSE RTC coin battery (CR 1220). | ||
| | | | ||
Connected Energy meter and configured Energy meter type in Installer menu are different. | Connected Energy meter and configured Energy meter type in Installer menu are different. | ||
| | |||
Unknown device detected. Check if the energy meter is compatible. | |||
| | | | ||
Reboot charger and check if the issue remains - contact support. | Reboot charger and check if the issue remains - contact support. | ||
|- | |- | ||
Latest revision as of 15:26, 24 April 2025
Main Page > TeltoCharge > Product guides > Troubleshooting GuideIntroduction
-
Here you can find information about Troubleshooting of our device.
What is the first thing to do when issue comes?
-
Usually, most of the issues gets solved by going through these simple steps below:
1. Go to Google play or APP store to update your mobile application version to the latest version.
2. Go to you charger settings and update charger Firmware version to the latest. (How to do it: FW update guide)
3. Go to your charger settings and reboot device.
How to check your charger firmware version?
-
Simple steps to finding a place in your mobile application where you can check your current TeltoCharge firmware version and update it to the latest. Please always check if you have latest firmware version in your charger.
1. Go to Teltonika Energy app settings and press Device info;
2. Press Check for updates;
3. At the top, current firmware version can be found.

How to download troubleshoot file?
-
Simple steps of finding place in your mobile application where you can download troubleshoot file.
1. Go to the Diagnostics.
2. Slide to the bottom.
3. Click Troubleshoot file.
4 Click Download troubleshoot file.
5. Wait until file downloaded message pop-up.
6. Select the downloaded file.
7. Click At the top right corner and press share
Note: For best results, please download the file during charging session. Then more details about current situation would be saved.

LED indicators
STATUS INDICATIONS
RED LED INDICATIONS (errors)
WARNINGS
| Simple CP detected | Temperature warning | Ventilation required | RTC time lost | Simplified CP denied | D state denied | Sensors not calibrated | Energy meter comm error | NFC init error | Low battery voltage | Emeter wrong type | E-meter unidetified | Main Board boot fail |
| Connected EV uses Simplified charging sequence. Charging power is limited to1 Phase 10 A; | Temperature higher than warning limit, current throttling
is present. |
EV requiring ventilation | EVSE date and time lost | Simplified CP detected and not allowed | EV requiring ventilation but charging location is not ventilated | Sensors were not calibrated during HW configuration | Energy meter communication error | NFC initialization error | Low battery voltage EVSE (RTC) | Energy meter configuration mismatch | Energy meter type unidentified | Main board is failing to boot |
|
Connected EV uses Simplified charging sequence. Charging power is limited. In installer menu option „Simplified charging sequence“ must be turned ON. |
Check if Charging location is sufficiently ventilated |
Check EVSE RTC coin battery (CR 1220) |
Connected EV uses Simplified charging sequence. Simplified CP charging is disabled in Installer menu. |
EV requiring ventilation, but Charging location is specified as not ventilated in Installer menu. |
Contact support. |
Check RS485 connection with external meter. Inspect cable. Check if meter is working. Make sure devices are configutated properly. |
Reboot charger and check if the issue remains. |
Check EVSE RTC coin battery (CR 1220). |
Connected Energy meter and configured Energy meter type in Installer menu are different. |
Unknown device detected. Check if the energy meter is compatible. |
Reboot charger and check if the issue remains - contact support. | |