==== RS485 parameters for energy meter Siemens PAC1020 ; PAC2200 ; PAC3100 ; PAC3120 ; Siemens PAC3200 ; Siemens PAC3220 ; Siemens PAC4200  ====
<div style="font-family:'Inter','Helvetica Neue',Arial,sans-serif; line-height:1.6;">
''Note: Energy meter parameters should match EVSE default parameters.''


{| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;"
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">RS-485 parameters for Siemens PAC1020, PAC2200, PAC3100, PAC3120, PAC3200, PAC3220 and PAC4200</span> ==
 
''Note: The energy meter's parameters must match the EVSE (charger) parameters. The default values are listed below.''
 
{| class="wikitable" style="text-align:center; width:80%;"
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | RS-485 parameter
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | EVSE (charger) default value (configurable in the app)
|-
|-
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | RS485 parameter
| Modbus address || 126
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | EVSE default parameter value (configurable in mobile app)
|-
|-
| style="padding: 8px;" | Modbus adress
| Baud rate || 19200
| style="padding: 8px;" | 126
|-
|-
| style="padding: 8px;" | Baud rate
| Parity || None
| style="padding: 8px;" | 19200
|-
|-
| style="padding: 8px;" | Parity
| Stop bits || 2
| style="padding: 8px;" | None
|}
 
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Configuring the meter in the mobile application</span> ==
 
''Note: You can use two meters with different addresses. Both meters share the same settings in the installer menu.''
 
# Make sure your charger firmware and application are updated to the latest version (see [[Release notes: Firmware]] and the app for [https://apps.apple.com/lt/app/teltonika-energy/id1618750750 iOS] / [https://play.google.com/store/apps/details?id=com.teltonika.ems.ev&hl=en&gl=US Android]).
# Enter the Installer menu, select Load Balancing, then Modbus RTU.<br>[[File:Settings-to-rtu.png|frameless|alt=Path to Modbus RTU settings|576x576px]]
# If the charger does not recognise the meter, go to Manual Setup and choose your meter model from the presets, or enter the values from the RS-485 parameters table manually.<br>[[File:Mod-to-manual.png|frameless|alt=Manual setup screen|576x576px]]


|-
Once the meter is successfully configured, press Connect. You will receive a confirmation screen and the status will change. Possible statuses:
| style="padding: 8px;" | Stop bits
* '''Connected''' – the meter is configured correctly.
| style="padding: 8px;" | 2
* '''Disconnected''' – a wrong parameter value is set on the charger, or the meter is not wired correctly.
* '''Wrong type''' – the meter configuration does not match the connected meter.
* '''Not supported''' – the connected meter is not compatible with the installation.


|}
For detailed settings, refer to the energy meter's official documentation.


</div>


← [[Smart energy meters]]
[[Category:Smart energy meter mastersheet]]

Latest revision as of 13:37, 28 October 2026

Main Page > Main Page EVC2 > Smart energy meter mastersheet > Siemens settings

RS-485 parameters for Siemens PAC1020, PAC2200, PAC3100, PAC3120, PAC3200, PAC3220 and PAC4200

Note: The energy meter's parameters must match the EVSE (charger) parameters. The default values are listed below.

RS-485 parameter EVSE (charger) default value (configurable in the app)
Modbus address 126
Baud rate 19200
Parity None
Stop bits 2

Configuring the meter in the mobile application

Note: You can use two meters with different addresses. Both meters share the same settings in the installer menu.

  1. Make sure your charger firmware and application are updated to the latest version (see Release notes: Firmware and the app for iOS / Android).
  2. Enter the Installer menu, select Load Balancing, then Modbus RTU.
    Path to Modbus RTU settings
  3. If the charger does not recognise the meter, go to Manual Setup and choose your meter model from the presets, or enter the values from the RS-485 parameters table manually.
    Manual setup screen

Once the meter is successfully configured, press Connect. You will receive a confirmation screen and the status will change. Possible statuses:

  • Connected – the meter is configured correctly.
  • Disconnected – a wrong parameter value is set on the charger, or the meter is not wired correctly.
  • Wrong type – the meter configuration does not match the connected meter.
  • Not supported – the connected meter is not compatible with the installation.

For detailed settings, refer to the energy meter's official documentation.