Electrical Specifications
Appearance
Main Page > TeltoCharge > General information > Electrical Specifications
| AC INPUT SPECIFICATIONS | |||
|---|---|---|---|
| 7,4 kW | 11 kW | 22 kW | |
| Input AC power connection | 1 phase | 3 phases | 3 phases |
| Input voltage | 22 to 240 VAC | 380 to 415 VAC | 380 to 415 VAC |
| Rated frequency | 50 / 60 HZ | ||
| Standby power consumption | 4 W | ||
| Earth (ground) fault protection | 30 mA AC, 6 mA DC | ||
| Overvoltage category | CAT III | ||
| Protection against electric shock | Class I | ||
| AC Output specifications | |||
| AC output voltage range | 220 - 240V AC | 380 - 415V AC | 380 - 415V AC |
| Connection Standart | Type 2 cable
Type 2 socket | ||