Changes

1,491 bytes added ,  08:30, 3 July 2023
m
no edit summary
Line 20: Line 20:  
Once the charger is properly connected to the electrical grid and interconnected with energy meter, the next step is to configure the settings using the Teltonika Energy app. Below, you will find a comprehensive list of the settings that should be adjusted to achieve DLM functionality.
 
Once the charger is properly connected to the electrical grid and interconnected with energy meter, the next step is to configure the settings using the Teltonika Energy app. Below, you will find a comprehensive list of the settings that should be adjusted to achieve DLM functionality.
    +
=== General meter settings ===
 +
[[File:2023-07-03 07 45 16-Window.png|right|frameless|276x276px]]
 +
If you want to enable solar functionality, it is important to correctly configure the general meter settings and dynamic load balancing settings
    +
# '''Energy meter type''': You need to select the type of smart meter (1-phase/3-phase). Please note that you can use a 1-phase charger even if the meter is 3-phase.
 +
# '''RS-485 baud rate''': This information can be found in the meter settings accessible through the meter display. If the client cannot locate it, it is recommended to refer to the smart meter manual.
 +
# '''RS-485 parity/stop bit''': Similarly, this information can also be found in the meter settings. If the client is unable to find it, it is advisable to check the smart meter manual.
 +
 +
=== Dynamic Load Balancing ===
 +
[[File:2023-07-03 07 51 37-Window.png|right|frameless|271x271px]]
 +
 +
# '''Measuring device''': The meter should be selected. For UK chargers, it is possible to choose CT clamps.
 +
# '''Energy meter address''': This information can be found in the meter settings accessed through the meter display. If the address cannot be located, it is recommended to consult the smart meter manual.
 +
# '''Current update interval''': By default, it is set to 3 seconds. However, there may be cases where the user needs to increase this value. For instance, if there are significant distances between the chargers and the smart meter or if there are numerous interconnected chargers.
          
<ul style="list-style-type: none; margin: 0; padding: 0;">
 
<ul style="list-style-type: none; margin: 0; padding: 0;">

Navigation menu