Changes

Line 8: Line 8:       −
''By default this status is set to AUTO''
+
''By default this status is set to AUTO''<br>
 +
''Settings can only be found in socket variant products''
    
=Authorization=
 
=Authorization=
Line 20: Line 21:     
''By default authorization status is set to OFF, user can set this status during the first set-up wizard.''
 
''By default authorization status is set to OFF, user can set this status during the first set-up wizard.''
 +
 +
=NFC=
 +
For personalized authorization, there is possibility to add and use NFC cards. Just press "Add new card", name your card and then touch the NFC card to the side of the charger. It should say "Card added successfully".
 +
 +
More information about NFC cards pairing can be found [[NFC FAQ|here]].
 +
 +
 +
''By default, NFC cards whitelist is empty.''
    
=Load balancing=
 
=Load balancing=
It is possible to set maximum amperage at which charger can operate. User can change current from 6 Amps to the maximum value, which was set by the Installer inside the Installer Settings.
+
Inside load balancing menu user can lower or increase current up to the value which was set by the installer in Installer menu. <br>
 +
For example: you set 32 A in Installer menu option '''Max power from grid''', so in user menu option '''Load balancing''' you will be able to set limitation from 6 A to 32 A.
    +
''By default load balancing is set to 10 A, user can increase this value when he increases Max power from grid option in Installer menu.''
   −
''By default this setting is set to 10 Amps''
+
= Schedule =
 +
There is an option to configure individual charging times in order to plan electricity usage or the effectiveness of the electrical grid.<br>
   −
=NFC=
+
* For the time periods when the car should not be charged, select the ‘Peak hours’ section.<br>
For personalized authorization, there is possibility to add and use NFC cards. Just press "Add new card", name your card and then touch the NFC card to the side of the charger. It should say "Card added successfully".
+
*
 +
* For time periods when the car should be charged, select the ‘Schedule‘ section (click on the '''+''' icon in the upper right corner).<br>
 +
 
 +
To set charging schedules, choose the desired hours and minutes on the provided clock.<br>
 +
 
 +
The ‘Repeat schedule‘ function repeats every week on the selected days.
 +
When the ‘Repeat schedule‘ function is disabled, the selected charging schedule will be set only for the week ahead and will stop after the last set day. In this case, the ‘Enable schedule charging‘ function will be automatically disabled. If the ‘Start time‘ is set in the past, the schedule will be active on the next selected day of the week. For example, if the current time is 10 AM on Friday, but the ‘Start time‘ is scheduled for 9 AM on Friday, it will only be active on the following Friday at 9 AM.<br>
 +
 
 +
The ‘Enable schedule charging‘ function will be disabled at midnight after the end of a schedule.
 +
It is important to optimize the active schedules and ensure that they do not overlap. '''Charger will not allow to save active overlapping schedules.''' However, when schedules are disabled, it can be saved.<br>
 +
 
 +
If peak hours are set for one time and scheduled charging hours are set later on the same day, there is a contradiction between these two conditions, and the EV will not be charged during the period between them. For example, if peak hours are set from 2 PM to 3 PM and regular scheduled charging hours are set from 5 PM to 7 PM, the EV will be charged only from 5 PM to 7 PM.
 +
 
 +
= Randomized delay =
 +
The randomized delay function provides an additional layer of protection against grid overloading. In the following cases, a random delay of up to 10 minutes will be applied:
 +
 
 +
* ''When a vehicle is connected and attempting to initiate the charging process for the first time.''
 +
* ''At the beginning and end of each scheduled charging session.''
 +
* ''After TeltoCharge has been restarted, rebooted, or turned off.''
 +
 
 +
Although this feature is enabled, it can be manually interrupted by swiping the App slider or using an NFC card.<br>
 +
 
 +
Using the Randomized delay function along with scheduled charging hours, the EV will only begin charging after waiting for the scheduled time and adding a randomized delay of up to 10 minutes. Similarly, a randomized delay will be applied to the scheduled end of charging.<br>
 +
 
 +
If the EV charging process is interrupted (e. g. temporary power outage), the randomized delay will still be in effect when the power is restored, further delaying the start of charging.<br>
   −
More information about NFC cards pairing can be found [[NFC FAQ|here]].
+
When OCPP is turned on, the Randomized delay functionality will not be active.
    +
= Errors and warnings =
 +
If TeltoCharge is not working correctly and giving errors or warnings, you will now be able to see more information in the app. All errors and warnings will be sent to the app in real-time.
 +
For all the details check: [https://wiki.teltonika-energy.com/view/LED_indicators LED indicators list]
    +
= Live data =
 +
Live data from TeltoCharge. It will be possible to see such data as:
   −
''By default, NFC cards whitelist is empty.''
+
* ''Charging type''
 +
* ''Phase used''
 +
* ''Temperature''
 +
* ''Max allowed current''
 +
* ''Phase voltages (input and output)''
    
= Connectivity=
 
= Connectivity=
Line 44: Line 89:  
To connect Teltocharge to Wi-Fi, just follow these steps:
 
To connect Teltocharge to Wi-Fi, just follow these steps:
   −
*Open Wi-Fi tab;
+
*''Open Wi-Fi tab;''
*Enable it with the slider;
+
*''Enable it with the slider;''
*Select your network from provided list;
+
*''Select your network from provided list;''
*Insert password and press save;
+
*''Insert password and press save;''
*Wait until product is connected successfully;
+
*''Wait until product is connected successfully;''
    
==Mobile ==
 
==Mobile ==
 +
''Optional. About possible purchase ask your sales manager'' <br/>
 
To connect TeltoCharge to cellular data first of all nano SIM card have to be inserted to the SIM card port. After that just enable Mobile Internet in the Connectivity tab with the slider.
 
To connect TeltoCharge to cellular data first of all nano SIM card have to be inserted to the SIM card port. After that just enable Mobile Internet in the Connectivity tab with the slider.
   Line 62: Line 108:     
==OCPP==
 
==OCPP==
Open Charge Point Protocol 1.6 is used to connect TeltoCharge to 3rd party Cloud servers. At the moment charger is able to achieve ''"Core"'' and ''"Local auth list management"'' functions.
+
Open Charge Point Protocol 1.6 is used to connect TeltoCharge to 3rd party Cloud servers. At the moment charger is able to achieve ''"Core"'', ''"Local auth list management"'' and ''"Smart charging"'' functions.
    
Before connecting TeltoCharge to any 3rd party Charge point management server, firstly check if server is compatible with OCPP 1.6 JSON.
 
Before connecting TeltoCharge to any 3rd party Charge point management server, firstly check if server is compatible with OCPP 1.6 JSON.
Line 68: Line 114:  
If server provider supports this OCPP version, to connect, user needs to type in server URL address and Charge point identity. After all settings are set, enable OCPP with a slider and press Save at the bottom of the screen. User also can see status if charger was connected successfully or not.
 
If server provider supports this OCPP version, to connect, user needs to type in server URL address and Charge point identity. After all settings are set, enable OCPP with a slider and press Save at the bottom of the screen. User also can see status if charger was connected successfully or not.
   −
More information anout OCPP you can find [[OCPP FAQ|here]].
+
More information about OCPP you can find [[OCPP FAQ|here]].
    
==Ethernet ==
 
==Ethernet ==
Line 75: Line 121:  
In order to be able to type configuration manually, user have to disable DHCP setting beforehand. DHCP slider can be found in the same Ethernet parameters window.  
 
In order to be able to type configuration manually, user have to disable DHCP setting beforehand. DHCP slider can be found in the same Ethernet parameters window.  
   −
=Date & Time=
+
==Date & Time==
In this tab user can set date and time according to the region in which product is going to be used. It is recommended to synchronize time with phone (button for this action is provided).  
+
In this tab user can set date and time according to the region in which product is going to be used. '''It is recommended to synchronize''' time with phone (button for this action is provided).
    
=Device info=
 
=Device info=
Line 82: Line 128:     
Also there is a possibility to restore default settings. With this function TeltoCharge restore all settings to default values except from the Installer Menu ones.  
 
Also there is a possibility to restore default settings. With this function TeltoCharge restore all settings to default values except from the Installer Menu ones.  
 +
<br>
    
After pressing '''Check for updates''', new window pops up, where user/installer can see information about current FW and update it.
 
After pressing '''Check for updates''', new window pops up, where user/installer can see information about current FW and update it.
 +
 +
==Diagnostics==
 +
 +
Here you can download troubleshoot file. <br>
 +
It will be used only by the Customer support engineers while solving risen issues.
    
=Installer menu=
 
=Installer menu=
Line 101: Line 153:       −
''By default this setting is set to 10 Amps''
+
'' By default this setting is set to 10 Amps''
 
  −
==Supply voltage==
      +
== Supply voltage ==
 
*Installer can change supply voltage (''voltage between phase and neutral wires'')
 
*Installer can change supply voltage (''voltage between phase and neutral wires'')
 
*Different regions can have different supply voltages, so installer can set this value accordingly to the used voltage in the individual site;
 
*Different regions can have different supply voltages, so installer can set this value accordingly to the used voltage in the individual site;
      −
''By default this setting is set to 230 V''
+
''Global product: By default this setting is set to 230 V''<br>
 +
''North American product: By default this setting is set to 120 V''
    
==Upper voltage tolerance==
 
==Upper voltage tolerance==
Line 127: Line 179:       −
''By default this setting is turned OFF''
+
''By default this setting is turned OFF''<br>
 +
''Not available in North America products''
    
==Phase priority==
 
==Phase priority==
Line 136: Line 189:       −
''By default this setting is set to L1''
+
''By default this setting is set to L1''<br>
 +
''Not available in North America products''
    
==Dynamic load balancing==
 
==Dynamic load balancing==
Line 142: Line 196:       −
''By Default this setting is turned off''
+
''By Default this setting is turned off''<br>
 +
''Not available in North America products''
 +
 
 +
== Energy meter type selection ==
 +
Be able to choose energy meter type, which will be used for the load balancing. Meter type setting is available in the app and the setting has two options: 1 phase, 3 phase
 +
 
 +
== Use data from energy meter ==
 +
Option to use data from external energy meter for power consumption calculations. New setting in the app for activating this function. Total values from energy meter also will be used in the OCPP. When this function is activated, dynamic load balancing function will not be active.
    
==Use preferred phase==
 
==Use preferred phase==
 
This function can be used if Dynamic load balancing is ON. With this feature installer can enable charger to use Preferred phase for charging process.
 
This function can be used if Dynamic load balancing is ON. With this feature installer can enable charger to use Preferred phase for charging process.
    +
''By default this setting is turned off''
 +
==Difference between phases==
 +
This function let user to select how theirs power input is wired - in Star network or Delta network style. <br>
 +
120° - Star (Wye) and Delta; <br>
 +
180° - Delta and split phase.
   −
''By default this setting is turned off''
+
In the case of Europe, most Star (Wye) and Delta connections will have a phase difference of 120°. In North America, the phase shift can be 180° when split phase connection type is used or in the case of Delta connection with center tap on one leg.
   −
==Connection type==
+
''Note: these parameters are used only for the power consumption (kWh) calculations and not influence operation of the charger.''
This function let user to select how theirs power input is wired - in Star network or Delta network style.
     −
''By default this setting is marked as Star''
+
''Global product: By default this setting is marked as 120° ''<br>
 +
''North American product: By default this setting is marked as 180°''
    
==Use neutral as phase==
 
==Use neutral as phase==
 
This function allows user to use electrical network without Neutral wire. L1 then must be connected to N(L1) pin in input terminal.
 
This function allows user to use electrical network without Neutral wire. L1 then must be connected to N(L1) pin in input terminal.
   −
''By default this setting is turned off''
+
''Global product: By default this setting is turned OFF''<br>
 +
 
 +
''North American product: By default this setting is turned ON''
    
==Allow simplified charging sequence==
 
==Allow simplified charging sequence==
Line 172: Line 240:     
If TeltoCharge is installed outside, set this setting to ''YES.''
 
If TeltoCharge is installed outside, set this setting to ''YES.''
  −
      
''By default this setting is set to NO''
 
''By default this setting is set to NO''
Line 188: Line 254:  
After this reset yellow LEDs starts blinking which means that charger requires to set-up Installer menu again.
 
After this reset yellow LEDs starts blinking which means that charger requires to set-up Installer menu again.
   −
=Reboot device=
+
==Reboot device==
 
There is a possibility to reboot charger through the Teltonika Energy app.
 
There is a possibility to reboot charger through the Teltonika Energy app.
   −
[[Category: Mobile app]]
+
[[Category: Product guides]]