|1.
 
|1.
|If Dynamic Load balancing is enabled
+
|How TeltoCharge sets maximum charging power when 3-phase charging is enabled?
|
+
|TeltoCharge checks which phase is loaded most, measures how much free current is available, and sets that current.
 
|-
 
|-
 
|2.
 
|2.
Line 33: Line 33:  
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled?
 
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled?
 
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 ampers higher then the charging phase, TeltoCharge will change charging phase to least loaded.
 
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 ampers higher then the charging phase, TeltoCharge will change charging phase to least loaded.
|-
  −
|7.
  −
|How TeltoCharge sets maximum charging power when 3-phase charging is enabled?
  −
|TeltoCharge checks which phase is loaded most, measures how much free current is available, and sets that current.
   
|}
 
|}
 +
 +
 +