Line 5: Line 5:  
|-
 
|-
 
|1.
 
|1.
|If Dynamic Load balancing is enabled
+
|How TeltoCharge sets maximum charging power when 3-phase charging is enabled?
|
+
|TeltoCharge checks which phase is loaded most, measures how much free current is available, and sets that current.
 
|-
 
|-
 
|2.
 
|2.
 
|Can I use simplified charging sequence with Dynamic load balancing.
 
|Can I use simplified charging sequence with Dynamic load balancing.
|Yes, there is possibility to use both features together, but there are some limitations which are regulated by the standard:
+
|Yes, there is possibility to use both features together, but there are some limitations which are regulated by the standard (IEC 61851-1 / SAE J1772):
    
# Maximum charging current is only 10 Ampers.
 
# Maximum charging current is only 10 Ampers.
Line 17: Line 17:  
|3.
 
|3.
 
|Can I use 3-phase smart meter for single phase charger?
 
|Can I use 3-phase smart meter for single phase charger?
|No, there is no possibility to use 1-phase charger with 3-phase smart meter.
+
|Yes, there is possibility to use 1-phase charger with 3-phase smart meter. Please refer to the Energy meter instruction sheet to configure it properly. It is required to select single phase meter in the TeltoCharge application settings.
 
|-
 
|-
 
|4.
 
|4.
Line 24: Line 24:  
|-
 
|-
 
|5.
 
|5.
|If phase priority is enabled, can charger automatically change phase?
+
|If "''use preferred phase''" is enabled, can charger automatically change phase?
 
|Yes, If TeltoCharge detects that prioritized phase is loaded and the maximum current it can give is 7 or less ampers, charger will make a check If other phases are loaded less:  
 
|Yes, If TeltoCharge detects that prioritized phase is loaded and the maximum current it can give is 7 or less ampers, charger will make a check If other phases are loaded less:  
   −
* If there is other phase which is loaded less, charger will chnage charging phase.  
+
* If there is other phase which is loaded less, charger will change charging phase.  
* If other two phases ar loaded charger will stop charging process.
+
* If other two phases are loaded as well, charger will stop charging process.
 
|-
 
|-
 
|6.
 
|6.
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled?
+
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled? [[/]]
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 ampers higher then the charging phase, TeltoCharge will change charging phase to least loaded.
+
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 amperes higher then the charging phase, TeltoCharge will change charging phase to the least loaded. [[1]]
|-
  −
|7.
  −
|How TeltoCharge sets maximum charging power when 3-phase charging is enabled?
  −
|TeltoCharge checks which phase is loaded most, measures how much free current is available, and sets that current.
   
|}
 
|}