Changes

no edit summary
Line 17: Line 17:  
|3.
 
|3.
 
|Can I use 3-phase smart meter for single phase charger?
 
|Can I use 3-phase smart meter for single phase charger?
|No, there is no possibility to use 1-phase charger with 3-phase smart meter.
+
|Yes, there is possibility to use 1-phase charger with 3-phase smart meter. Please refer to the Energy meter instruction sheet to configure it properly. It is required to select single phase meter in the TeltoCharge application settings.
 
|-
 
|-
 
|4.
 
|4.
Line 27: Line 27:  
|Yes, If TeltoCharge detects that prioritized phase is loaded and the maximum current it can give is 7 or less ampers, charger will make a check If other phases are loaded less:  
 
|Yes, If TeltoCharge detects that prioritized phase is loaded and the maximum current it can give is 7 or less ampers, charger will make a check If other phases are loaded less:  
   −
* If there is other phase which is loaded less, charger will chnage charging phase.  
+
* If there is other phase which is loaded less, charger will change charging phase.  
* If other two phases ar loaded charger will stop charging process.
+
* If other two phases are loaded as well, charger will stop charging process.
 
|-
 
|-
 
|6.
 
|6.
 
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled? [[/]]
 
|How TeltoCharge prioritizes phases when phase priority is disabled, TeltoChagre connected to three phases and three phase charging is disabled? [[/]]
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 ampers higher then the charging phase, TeltoCharge will change charging phase to least loaded. [[1]]
+
|Charger checks which phase is least loaded and selects that phase as a charging phase. If during charging process any of other two phases load decreases and the maximum available current will be 5 amperes higher then the charging phase, TeltoCharge will change charging phase to the least loaded. [[1]]
 
|}
 
|}
  −
  −
[[Category: FAQ]]