Main Page > TeltoCharge > Advanced Topics > Dynamic Load Balancing

DYNAMIC LOAD BALANCING

TeltoCharge have the ability to communicate with dedicated smart energy meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet user habits. Smart energy meter should always be installed in source electrical cabinet as showed below.  

Smart meter and TeltoCharge communication

Smart meter and TeltoCharge communicates via Modbus RS-485 protocol. In order to achieve smooth communication, it is recommended to use communication cable according to this protocol. Check example below

Note: Communication cable should be integrated with power cable.

Supported energy meters

In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided bellow.  

TeltoCharge supported energy meter list:

Energy meter manufacturer Model Supported type for Dynamic load balancing Datasheet
Carlo Gavazzi series 1 EM111
See here EM111
EM112
See here EM112
ET112 See here ET112
Carlo Gavazzi series 3 EM330
See here EM330
EM340
See here EM340
ET330 See here ET330
ET340 See here ET340
Carlo Gavazzi series 5 EM530
EM530
EM540
EM540
More coming soon...

RS485 parameters for energy meter

Note: Energy meter parameters should match EVSE default parameters.

RS485 parameter EVSE default parameter value (non-configurable)
Modbus adress 1
Baud rate 9600
Parity none
Stop bits 1

Carlo Gavazzi meters wiring:

Note: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.  

3rd and 5th series to TeltoCharge connection
1st series to TeltoCharge connection

Powering the energy meter

To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.