TeltoCharge have the ability to communicate with dedicated smart energy meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet user habits. Smart energy meter should always be installed in source electrical cabinet as showed below.  
 
TeltoCharge have the ability to communicate with dedicated smart energy meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet user habits. Smart energy meter should always be installed in source electrical cabinet as showed below.  
 
[[File:Dynamic Load Balancing Conection Schematic.png|alt=|center|frameless|395x395px]]
 
[[File:Dynamic Load Balancing Conection Schematic.png|alt=|center|frameless|395x395px]]
Line 5: Line 5:  
==== Smart meter and TeltoCharge communication ====
 
==== Smart meter and TeltoCharge communication ====
 
Smart meter and TeltoCharge communicates via Modbus RS-485 protocol. In order to achieve smooth communication, it is recommended to use communication cable according to this protocol. Check example below
 
Smart meter and TeltoCharge communicates via Modbus RS-485 protocol. In order to achieve smooth communication, it is recommended to use communication cable according to this protocol. Check example below
[[File:TeltoCharge DLB CableExample.png|center|frameless|387x387px]]
+
[[File:TeltoCharge DLB CableExample.png|center|frameless|387x387px|
   −
=== Supported energy meters ===
  −
In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided bellow.  
     −
Note: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.  
+
]]'''Note:''' ''Communication cable should be integrated with power cable.''
   −
==== Carlo Gavazzi meters: ====
+
== Supported energy meters ==
 +
In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided below.  
   −
===== EM 3rd series to TeltoCharge connection =====
+
=== TeltoCharge supported smart energy meters ===  
[[File:TeltoCharge DLB CarloGavazzi 3phase.png|center|frameless|521x521px]]
     −
===== EM 1st series to TeltoCharge connection =====
+
{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 60%;"
[[File:TeltoCharge DLB CarloGavazzi 1phase.png|center|frameless|524x524px]]
+
|-
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Technical information
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Configuration in mobile application
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Wiring scheme
   −
===== Powering the energy meter =====
+
|-
To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.
+
| style="padding: 2px;" | Carlo Gavazzi series 1-3 <br>
 +
| style="padding: 2px;" | [[EM and ET models]] <br>
 +
| style="padding: 2px;" | [[Carlo Gavazzi settings]]
 +
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/view/EM_and_ET_models#Carlo_Gavazzi_meters_wiring: METER -> TELTOCHARGE] <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | Siemens PACxxxx <br>
 +
| style="padding: 2px;" | [[PAC models]] <br>
 +
| style="padding: 2px;" | [[Siemens settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | ABB A4x ; B2x <br>
 +
| style="padding: 2px;" | [[A and B models]] <br>
 +
| style="padding: 2px;" | [[ABB settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | Eastron SDMxx <br>
 +
| style="padding: 2px;" | [[SDM models]] <br>
 +
| style="padding: 2px;" | [[Eastron settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | Inepro PRO380 <br>
 +
| style="padding: 2px;" | [[PRO model]]
 +
| style="padding: 2px;" | [[Inepro settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
 
 +
| style="padding: 2px;" | Chint <br>
 +
| style="padding: 2px;" | [[Chint models]]
 +
| style="padding: 2px;" | [[Chint settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
 
 +
| style="padding: 2px;" | Entes <br>
 +
| style="padding: 2px;" | [[ES models]]
 +
| style="padding: 2px;" | [[Entes settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
|-
 +
| style="padding: 2px;" | Acrel <br>
 +
| style="padding: 2px;" | [[Acrel models]]
 +
| style="padding: 2px;" | [[Acrel settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
|-
 +
 
 +
| style="padding: 8px;" colspan="4" | ''More coming soon...''
 +
|-
 +
 
 +
 
 +
 
 +
|}
 +
 
 +