== DYNAMIC LOAD BALANCING ==
 +
TeltoCharge have the ability to communicate with dedicated smart energy meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet user habits. Smart energy meter should always be installed in source electrical cabinet as showed below.  
 +
[[File:Dynamic Load Balancing Conection Schematic.png|alt=|center|frameless|395x395px]]
   −
'''DYNAMIC LOAD BALANCING'''
+
==== Smart meter and TeltoCharge communication ====
 +
Smart meter and TeltoCharge communicates via Modbus RS-485 protocol. In order to achieve smooth communication, it is recommended to use communication cable according to this protocol. Check example below
 +
[[File:TeltoCharge DLB CableExample.png|center|frameless|387x387px|
   −
Product have the ability to connect with dedicated Smart meter and regarding to its readings, adjust used electrical power. Such functionality allows to protect house electrical grid from overload in peak hours and optimize energy usage to meet users habits. Smart meter will always be installed in source electrical cabinet as showed below. Dynamic Load Balancing checks how busy the house grid is and lets the charger know, to increase or decrease charging power accordingly.
  −
[[File:Dynamic Load Balancing Conection Schematic.png|alt=|center|frameless|320x320px]]'''Smart Meter and TELTOCHARGE wiring'''
     −
Picture provided bellow, show where Energy Meter connection pins are located. Because Energy meters can have individual, unique pins layout, please pay attention to the pin names and placing in TeltoCharge product. Connection points in different Energy meters might vary.
+
]]'''Note:''' ''Communication cable should be integrated with power cable.''  
[[File:Energy Meter conection pins on Interface Board.png|center|frameless]]
  −
'''Supported Energy Meters'''
     −
In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. To reach all of the supported Smart Energy Meters and read how to connect them properly, scan provided QR code in Manual or follow this link: ''<u><Link to the list will be added soon></u>''
+
== Supported energy meters ==
 +
In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided below.  
 +
 
 +
=== TeltoCharge supported smart energy meters ===
 +
 
 +
{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 60%;"
 +
|-
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Technical information
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Configuration in mobile application
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Wiring scheme
 +
 
 +
|-
 +
| style="padding: 2px;" | Carlo Gavazzi series 1-3 <br>
 +
| style="padding: 2px;" | [[EM and ET models]] <br>
 +
| style="padding: 2px;" | [[Carlo Gavazzi settings]]
 +
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/view/EM_and_ET_models#Carlo_Gavazzi_meters_wiring: METER -> TELTOCHARGE] <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | Siemens PACxxxx <br>
 +
| style="padding: 2px;" | [[PAC models]] <br>
 +
| style="padding: 2px;" | [[Siemens settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | ABB A4x ; B2x <br>
 +
| style="padding: 2px;" | [[A and B models]] <br>
 +
| style="padding: 2px;" | [[ABB settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | Eastron SDMxx <br>
 +
| style="padding: 2px;" | [[SDM models]] <br>
 +
| style="padding: 2px;" | [[Eastron settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
| style="padding: 2px;" | Inepro PRO380 <br>
 +
| style="padding: 2px;" | [[PRO model]]
 +
| style="padding: 2px;" | [[Inepro settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
 
 +
| style="padding: 2px;" | Chint <br>
 +
| style="padding: 2px;" | [[Chint models]]
 +
| style="padding: 2px;" | [[Chint settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
 
 +
|-
 +
 
 +
| style="padding: 2px;" | Entes <br>
 +
| style="padding: 2px;" | [[ES models]]
 +
| style="padding: 2px;" | [[Entes settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
|-
 +
| style="padding: 2px;" | Acrel <br>
 +
| style="padding: 2px;" | [[Acrel models]]
 +
| style="padding: 2px;" | [[Acrel settings]]
 +
| style="padding: 2px;" | METER -> TELTOCHARGE <br>
 +
|-
 +
 
 +
| style="padding: 8px;" colspan="4" | ''More coming soon...''
 +
|-
 +
 
 +
 
 +
 
 +
|}
 +
 
 +
[[Category: Advanced Topics]]