Carlo Gavazzi settings
RS485 parameters for energy meter Carlo Gavazzi series 1; series 2; series 3
Note: Energy meter parameters should match EVSE default parameters.
| RS485 parameter | EVSE default parameter value (configurable in mobile app) |
|---|---|
| Modbus adress | 1 |
| Baud rate | 9600 |
| Parity | None |
| Stop bits | 1 |
Configuring the meter in the mobile application
Note: Users can use two meters with different addresses. Additionally, there will be settings for these energy meters in the installer menu (these settings are the same for both energy meters).
1. Make sure your charger firmware and application are updated to the latest version. (←Release notes: Firmware and iOS / Android).
2. Enter the installer menu, select Load Management or Load Balancing, then the communication type of the meter.
3. If the charger recognizes the meter, you can "Search for device". Otherwise, in Manual Setup, use a device preset or enter the settings from the RS485 parameters table manually.
For detailed settings, refer to the energy meter's official documentation.