Jump to content

Release notes: EV Charging App

From Teltonika Energy Wiki

Latest Application Version

Android OS

Version Date Android changes Preview Android bug fixes
V 1.18 date new pre new

iOS

Version Date iOS changes Preview iOS bug fixes
V 1.18 date new pre new

Previous Application versions

Android OS

Version Date Android changes Preview Android bug fixes
V 1.17 date new pre new
V 1.16 date
  • Improved pop-up keyboard responsiveness
  • Implemented Modbus TCP with dynamic IP addresses
  • Added automatic secondary device search via Modbus TCP
  • Added load management settings for TCP Primary devices
  • Introduced Dynamic load balancing for the Delta grid type
  • Added the EV Sleep feature for DLM
  • Added support for ABB smart meters
pre
  • Fixed wrong connection method logo being displayed immediately after connecting to the charger
  • Fixed Bluetooth connection persisting after factory reset
  • Adjusted incorrect values being allowed when "use neutral as phase" is enabled
  • Fixed user interface overlaps when more than four secondary device IPs are added
V 1.15 date
  • Added Homewizard P1 meter support
  • Automated the virtual keyboard pop-up when entering installer password
  • Prevented unnecessary CT and Smart Meter data from showing in Diagnostics if DLM is enabled
  • Made adding new NFC cards more convenient by showing the list of currently whitelisted cards
  • For "Use neutral as phase" setting, set voltage tolerances as percentages instead of numerical values
  • Added Shelly Pro 3EM TCP meter support
  • Added support for Android 16
  • Introduced a Demo mode, without requiring a physical charger
  • Added an option to turn off automatic 1-phase charging
  • Made it possible to disable grid detection and related settings within installer menu for troubleshooting purposes
  • Implemented an "LED Off" mode

pre

  • Removed unnecessary login and password fields within the app
  • Fixed secondary charger's live data amperage showing as imported from grid with static load management enabled
  • Fixed Android 15 only requesting one permission at a time
  • Removed redundant phone number field in Connectivity section
  • Fixed interface inconsistency with OCPP on and off
  • Fixed the "back" button in the installer menu
  • Removed the persisting "communicating" pop-up notification
  • Fixed Load Balancing not taking on the "max power from grid" configuration from the installer menu
  • Fixed not all CT clamps' data showing in diagnostics on certain EVC models
  • Adjusted device naming from TeltoCharge2 to EVC2

iOS

Version Date iOS changes Preview iOS bug fixes
V 1.17 date new pre new
V 1.16 date
  • Implemented Modbus TCP with dynamic IP addresses
  • Updated user interface elements to match other platforms
  • Added automatic secondary device search via Modbus TCP
  • Added load management settings for TCP Primary devices
  • Introduced Dynamic load balancing for the Delta grid type
  • Added the EV Sleep feature for DLM
  • Added support for ABB smart meters
pre
V 1.15 date
  • Implemented "Schedule, "View all usage", "Personalisation", "Device info", "Date and time", "Charging", "Settings list / NFC pairing", "Connectivity", "Diagnostics" sections.
  • Introduced a Demo mode, without requiring a physical charger
  • Added Homewizard P1 meter support
  • For "Use neutral as phase" setting, set voltage tolerances as percentages instead of numerical values
  • Added an option to turn off automatic 1-phase charging
  • Made it possible to disable grid detection and related settings within installer menu for troubleshooting purposes
  • Implemented an "LED Off" mode

pre

  • Fixed incorrect values showing after changing from kW to Amps during ongoing charging session
  • Fixed known app crashing behaviors
  • Fixed Bluetooth connection status not updating on loss of communication
  • Fixed previous charging session data adjusting incorrectly upon time and date changes
  • Adjusted device availability status showing incorrectly when multiple phones are used to access the charger at the same time
  • Added correct error code when entering incorrect installer codes
  • Removed invalid options from Fail-safe current selection
  • When DLB is off, the primary device type in DLM is now correctly shown as Static
  • Fixed L2 and L3 output voltage not showing in Diagnostics
  • Touched up user interface inconsistencies
  • Fixed ECO mode maximum voltage exceeding the "maximum voltage from grid" value
  • Adjusted device naming from TeltoCharge2 to EVC2

Updating