Jump to content

11 kW TeltoCharge (socket version) Electrical information

From Teltonika Energy Wiki
Revision as of 14:58, 6 August 2026 by FiodorF (talk | contribs) (11 kW TeltoCharge electrical specifications)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

11 kW TeltoCharge electrical specifications

TeltoCharge have different electrical specifications that depend on selected power, which is customizable to suit user needs.


AC INPUT SPECIFICATIONS
11 kW TeltoCharge
Input AC power connection 1 phase or 3 phases
Maximum current 16 A
Input voltage 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC

Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range
3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC

Connection Standart Type 2 cable

Type 2 socket

Power Cable
Maximum cable diameter 17.5 mm
Maximum wire cross section 7.5 mm2