Jump to content

First Start Guide EVC2

From Teltonika Energy Wiki

Physical Device Installation Guide

INSTALLATION MANUAL

Press on the picture for shortened guide on how to physically install the device

First start guide

With easy-to-follow instructions, you'll be up and running in no time, making the most of your new experience.

Mandatory Steps
Step Explanation Information
Connect wires Connection type is detected automatically Link to all available connections/wirings
Pair Pairing code can be found on the sticker
Finish set-up Possibility to change currency, kWH price and name of charging station. Also add NFC card is necessary
Update FW After finish the set-up window, pop-up about available update will show up.

Proceed with the suggestion ||

Installer menu All important settings are hidden under secured menu that could be accessed with code
*Use caseBold text Different configuration examples. Link to use cases

Follow these detailed steps to get started with TeltoCharge in a correct way:

Step Number Description Notes Links
1 Download EV Charging APP For Android

For Apple

2 Pair Pairing code can be found on the sticker. Pairing process
3 Update device to the latest FW After pairing, choose your device in the menu, and a notification may suggest updating the firmware version. How to update
4 Configure your EVC2 Follow steps in device configuration guide and using Teltonika EV Charging app set parameters according to your site requirements. -

Configuration Setup Possibilities

Home Installation configuration with CT Clamps

Step Number Description Suggestions Links
1 CT clamp CT clamps installation option in the wiki link on the right CT clamps
2 Go to Installer Settings via EV Charging APP Enter the installers menu by entering the password Installer menu access
3 Go to Load Balancing section 1. Select CT Clamp as measuring device.

2. Enable Load Balancing and press on DLB CT button. (Before calibration, ensure at least one CT is connected to the device and that its measuring end is not clamped around the cable) 3. Calibrate your CT clamps.

How to enable CT clamps
4 Test setup 1. Plug in cable from charger to EV, but don't start charging.

2. Go to Diagnostics window in the app and check if Max allowed current is more than at least 6 A to start charging.

1. No limitations

2. Load balance limitations

Home Installation configuration with Modbus RTU meter

Step Number Description Suggestions Links
1 Modbus RTU meters Modbus RTU installation option in the wiki link on the right CT clamps
2 Go to Installer Settings via EV Charging APP Enter the installers menu by entering the password Installer menu access
3 Go to Load Balancing section 1. Select CT Clamp as measuring device.

2. Enable Load Balancing and press on DLB CT button. (Before calibration, ensure at least one CT is connected to the device and that its measuring end is not clamped around the cable) 3. Calibrate your CT clamps.

How to enable CT clamps
4 Test setup 1. Plug in cable from charger to EV, but don't start charging.

2. Go to Diagnostics window in the app and check if Max allowed current is more than at least 6 A to start charging.

1. No limitations

2. Load balance limitations