Electrical Specifications

From Wiki
Revision as of 12:09, 17 February 2022 by Rytimeci (talk | contribs) (Created page with "==Electrical Specifications== {| class="wikitable" style="text-align: center;" ! colspan="4" |AC INPUT SPECIFICATIONS |- | |7,4 kW |11 kW |22 kW |- |Input AC power connection...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > TeltoCharge > General information > Electrical Specifications

Electrical Specifications

AC INPUT SPECIFICATIONS
7,4 kW 11 kW 22 kW
Input AC power connection 1 phase 3 phases 3 phases
Input voltage 22 to 240 VAC 380 to 415 VAC 380 to 415 VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range 220 - 240V AC 380 - 415V AC 380 - 415V AC
Connection Standart Type 2 cable

Type 2 socket