PEN fault protection
From Wiki
Revision as of 12:25, 28 June 2023 by Vaidotas Seliukas (talk | contribs) (Added approximate contents)
BRIEF DESCRIPTION
PEN fault protection works by measuring current falling on PE wire.
If it reaches or goes over 20mA, product turns the relays OFF.
CT CLAMP WIRING
Product has integrated PEN fault protection.
In order to receive this functionality it is required to clamp internal current transformer onto PE cable as shown in the illustration above.
CONFIGURATION OF PEN FAULT PROTECTION
In order to enable PEN fault protection in your device, please follow these steps:
- Power ON your charging station
- Pair (if was not paired before)
- Enter Main settings in mobile application
- Enter Installer menu by typing in the Installer code
- Scroll to PME FAULT DETECTION section
- Enable PEN protection with the slider