7.4 kW TeltoCharge electrical specifications

TeltoCharge have different configurations, which can be customizable to suit user needs.


AC INPUT SPECIFICATIONS
7,4 kW
Input AC power connection 1 phase
Maximum current 32 A
Input voltage (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range
1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

Power Cable
Maximum cable diameter 17.5 mm
Maximum wire cross section 7.5 mm2