Changes

no edit summary
Line 16: Line 16:  
<br>1. Go to Teltonika Energy app settings, scroll down and press '''Device info'''; <br>2. Press '''Check for updates'''; <br>3. At the top, current firmware version can be found. <br>  
 
<br>1. Go to Teltonika Energy app settings, scroll down and press '''Device info'''; <br>2. Press '''Check for updates'''; <br>3. At the top, current firmware version can be found. <br>  
   −
[[File:F.png|border|frameless|317x317px|alt=]]                                                         [[File:Check update.png|frameless|316x316px]]                                             [[File:Newest fw.png|frameless|317x317px]]            
+
[[File:F.png|border|frameless|317x317px|alt=]]                                                                                                                                                                                 [[File:Check update.png|frameless|317x317px]]              
 
+
[[File:Newest fw.png|frameless|317x317px]]      
 
  <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">How to download troubleshoot file?</h2>
 
  <h2 style="color: #4a4a4a; font-size: 24px; font-weight: bold; margin-bottom: 10px;">How to download troubleshoot file?</h2>
 
   <ul style="list-style-type: none; margin: 0; padding: 0;">
 
   <ul style="list-style-type: none; margin: 0; padding: 0;">
Line 27: Line 27:  
4. '''Wait up to 20 s''' for troubleshoot file to be generated. <br>
 
4. '''Wait up to 20 s''' for troubleshoot file to be generated. <br>
 
5. Save file to your mobile phone and provide it to our Technical support departament.<br>
 
5. Save file to your mobile phone and provide it to our Technical support departament.<br>
      
'''Note:''' For best results, please download the file '''during charging session.''' Then more details about current situation would be saved.
 
'''Note:''' For best results, please download the file '''during charging session.''' Then more details about current situation would be saved.
 
<br>
 
<br>
 +
[[File:F.png|border|frameless|317x317px|alt=]]
 +
[[File:Check-updates.png|border|frameless|317x317px|alt=]]
 
<br>   
 
<br>   
   Line 60: Line 61:  
|White LED‘s rolling from the bottom to the top – shows that TeltoCharge is booting up
 
|White LED‘s rolling from the bottom to the top – shows that TeltoCharge is booting up
 
|White LED‘s rolling from the top to the bottom – shows that TeltoCharge is Reserved (OCPP only)
 
|White LED‘s rolling from the top to the bottom – shows that TeltoCharge is Reserved (OCPP only)
|White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action
+
| White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action
|Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings.
+
| Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings.
 
|Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required.
 
|Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required.
 
|Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C).
 
|Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C).
Line 79: Line 80:  
|
 
|
 
|Authorize yourself with app or NFC card.
 
|Authorize yourself with app or NFC card.
|1. Go to settings via Teltonika energy APP and select schedule time section to check for set graphs<br>
+
| 1. Go to settings via Teltonika energy APP and select schedule time section to check for set graphs<br>
 
2. Wait for more available power or increase amperage limits via settings (if your grid allows it)<br>
 
2. Wait for more available power or increase amperage limits via settings (if your grid allows it)<br>
 
3. Available power is less than 6 Amperes. Provide more power or wait for more to generate.<br>
 
3. Available power is less than 6 Amperes. Provide more power or wait for more to generate.<br>
Line 94: Line 95:  
!M
 
!M
 
!N
 
!N
! O
+
!O
 
|-
 
|-
 
|[[File:TeltoCharge LEDS AddNFC.gif|center|frameless]]
 
|[[File:TeltoCharge LEDS AddNFC.gif|center|frameless]]
Line 107: Line 108:  
|Green LED‘s pulsing - Initialisation of charging.
 
|Green LED‘s pulsing - Initialisation of charging.
 
|Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process.
 
|Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process.
|Green LED‘s on – TeltoCharge finished charging.
+
| Green LED‘s on – TeltoCharge finished charging.
|Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D).
+
| Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D).
|Red four middle LED's - NFC/RFID card declined from the server.
+
| Red four middle LED's - NFC/RFID card declined from the server.
 
|Green four middle LED's - NFC/RFID card accepted from the server.
 
|Green four middle LED's - NFC/RFID card accepted from the server.
 
|-
 
|-
Line 160: Line 161:     
Output current.
 
Output current.
|Current leakage detected
+
| Current leakage detected
 
|Cable lock;
 
|Cable lock;
 
PP fail;
 
PP fail;
Line 166: Line 167:  
Car diode.
 
Car diode.
 
|Temperature reached 85°C
 
|Temperature reached 85°C
| -12V;
+
| -12V;
 
|CP fail
 
|CP fail
 
|
 
|
 
Problems with energy meter:
 
Problems with energy meter:
*Unrecognized;
+
* Unrecognized;
 
*Badly set;
 
*Badly set;
 
*Communication problems;
 
*Communication problems;
 
Other problems:
 
Other problems:
 
*Temperature;
 
*Temperature;
*Current ;
+
* Current ;
 
*D state.
 
*D state.
 
|-
 
|-
Line 189: Line 190:  
|
 
|
 
*Disconnect the cable from the EV and check if the error persists.
 
*Disconnect the cable from the EV and check if the error persists.
* If the error is cleared, try to start charging. If the error occurs once again, try following steps:
+
*If the error is cleared, try to start charging. If the error occurs once again, try following steps:
*Check if charging cable is fully pluged into socket and/or EV;
+
* Check if charging cable is fully pluged into socket and/or EV;
 
*Check if the inside of both the socket and the plug has no foreign materials inside (is clean).
 
*Check if the inside of both the socket and the plug has no foreign materials inside (is clean).
 
*Check visually if the cable is not damaged.
 
*Check visually if the cable is not damaged.
* Check if the boards are not covered in dust and/or other materials.
+
*Check if the boards are not covered in dust and/or other materials.
 
|
 
|
 
*Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side;
 
*Check if the charging cable is connected correctly from the charger side (socket version) and from the EV side;
Line 199: Line 200:  
*Listen if you can hear a clicking sound from the TeltoCharge when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager.
 
*Listen if you can hear a clicking sound from the TeltoCharge when you plug the cable to EV. Charger should lock cable plug. If you can’t hear, try to unplug cable (from EVSE side) while it is plugged from EV side. If it is possible to unplug, report this problem via VIP helpdesk or your sales manager.
 
*If any of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard.
 
*If any of these steps helps, measure the voltage between PE and PP and check if it is in accordance to the standard.
 +
|
 +
*Check the temperature inside Teltonika Energy app > Device info. If temperature is higher than 85 ℃ wait while charger cools down.
 
|
 
|
*Check the temperature inside Teltonika Energy app > Device info. If temperature is higher than 85 ℃ wait while charger cools down.
  −
|
   
*Restart TeltoCharge
 
*Restart TeltoCharge
 
|  
 
|  
Line 208: Line 209:     
*Check connected wires via TeltoCharge and energy meter inputs;
 
*Check connected wires via TeltoCharge and energy meter inputs;
* Check if the energy meter is compatible;
+
*Check if the energy meter is compatible;
*Check temperature.
+
* Check temperature.
    
|-
 
|-
Line 223: Line 224:  
|-
 
|-
 
|Simple CP detected
 
|Simple CP detected
| Temperature warning
+
|Temperature warning
 
|Ventilation required
 
|Ventilation required
 
|RTC time lost
 
|RTC time lost
Line 229: Line 230:  
|D state denied
 
|D state denied
 
|Sensors not calibrated
 
|Sensors not calibrated
|Energy meter comm error
+
| Energy meter comm error
 
|NFC init error
 
|NFC init error
 
|Low battery voltage
 
|Low battery voltage
Line 239: Line 240:  
| colspan="13" |<center><big>'''Meaning'''</big></center>
 
| colspan="13" |<center><big>'''Meaning'''</big></center>
 
|-
 
|-
| Connected EV uses Simplified charging sequence. Charging power is limited to1 Phase 10 A;
+
|Connected EV uses Simplified charging sequence. Charging power is limited to1 Phase 10 A;
    
|Temperature higher than warning limit, current throttling  
 
|Temperature higher than warning limit, current throttling  
 
is present.
 
is present.
   −
|EV requiring ventilation
+
| EV requiring ventilation
 
|EVSE date and time lost
 
|EVSE date and time lost
 
|Simplified CP detected and not allowed
 
|Simplified CP detected and not allowed
Line 252: Line 253:  
|NFC initialization error
 
|NFC initialization error
 
|Low battery voltage EVSE (RTC)
 
|Low battery voltage EVSE (RTC)
|Energy meter configuration mismatch
+
| Energy meter configuration mismatch
| Energy meter type unidentified
+
|Energy meter type unidentified
 
|Main board is failing to boot
 
|Main board is failing to boot
   Line 279: Line 280:  
|
 
|
 
Check EVSE RTC coin battery (CR 1220).
 
Check EVSE RTC coin battery (CR 1220).
|
+
|  
 
Connected Energy meter and configured Energy meter type in Installer menu are different.
 
Connected Energy meter and configured Energy meter type in Installer menu are different.
|
+
|  
 
Unknown device detected. Check if the energy meter is compatible.
 
Unknown device detected. Check if the energy meter is compatible.
 
|
 
|