==Connection type==
+
==Difference between phases==
This function let user to select how theirs power input is wired - in Star network or Delta network style.
+
This function let user to select how theirs power input is wired - in Star network or Delta network style. <br>
 +
120° - Star (Wye) and Delta; <br>
 +
180° - Delta and split phase.
   −
''Global product: By default this setting is marked as Star''<br>
+
In the case of Europe, most Star (Wye) and Delta connections will have a phase difference of 120°. In North America, the phase shift can be 180° when split phase connection type is used or in the case of Delta connection with center tap on one leg.
''North American product: By default this setting is marked as Delta''
+
 
 +
''Note: these parameters are used only for the power consumption (kWh) calculations and not influence operation of the charger.''
 +
 
 +
''Global product: By default this setting is marked as 120° ''<br>
 +
''North American product: By default this setting is marked as 180°''
    
==Use neutral as phase==
 
==Use neutral as phase==