In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided bellow.  
 
In order to strive for wider applicability and compatibility, we constantly test and add new supported devices into list. All of the supported Energy meters and schematics how to connect them are provided bellow.  
   −
Note: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.  
+
==== TeltoCharge supported energy meter list: ====
 +
{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 60%;"
 +
|-
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Model
 +
|-
 +
| style="padding: 8px;" | Carlo Gavazzi series 1
 +
| style="padding: 8px;" |
 +
EM111 <br>
 +
EM112 <br>
 +
ET112 <br>
 +
|-
 +
| style="padding: 8px;" | Carlo Gavazzi series 3
 +
| style="padding: 8px;" |
 +
EM330 <br>
 +
EM340 <br>
 +
ET330 <br>
 +
ET340 <br>
 +
|-
 +
| style="padding: 8px;" | Carlo Gavazzi series 5
 +
| style="padding: 8px;" |
 +
EM530 <br>
 +
EM540 <br>
 +
|-
 +
| style="padding: 8px;" colspan="2" | ''More coming soon...''
 +
|}
   −
==== Carlo Gavazzi meters: ====
+
==== RS485 parameters for energy meter ====
 +
''Note: Energy meter parameters should match EVSE default parameters.''
 +
 
 +
{| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;"
 +
|-
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | RS485 parameter
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | EVSE default parameter value (non-configurable)
 +
|-
 +
| style="padding: 8px;" | Modbus adress
 +
| style="padding: 8px;" | 1
 +
|-
 +
| style="padding: 8px;" | Baud rate
 +
| style="padding: 8px;" | 9600
 +
|-
 +
| style="padding: 8px;" | Parity
 +
| style="padding: 8px;" | none
 +
 
 +
|-
 +
| style="padding: 8px;" | Stop bits
 +
| style="padding: 8px;" | 1
 +
 
 +
|}
 +
 
 +
==== Carlo Gavazzi meters wiring: ====
 +
 
 +
''Note: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.  ''
    
===== EM 3rd series to TeltoCharge connection =====
 
===== EM 3rd series to TeltoCharge connection =====