AC INPUT SPECIFICATIONS
7,4 kW 11 kW 22 kW
Input AC power connection 1 phase 3 phases 3 phases
Input voltage 22 to 240 VAC 380 to 415 VAC 380 to 415 VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range 220 - 240V AC 380 - 415V AC 380 - 415V AC
Connection Standart Type 2 cable

Type 2 socket