11 kW TeltoCharge Electrical information
11 kW TeltoCharge electrical specifications
TeltoCharge have different electrical specifications who depends on selected power, which can be customizable to suit user needs.
AC INPUT SPECIFICATIONS | |||
---|---|---|---|
11 kW TeltoCharge | |||
Input AC power connection | 1 phase or 3 phases | ||
Maximum current | 16 A | ||
Input voltage | 3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC | ||
Rated frequency | 50 / 60 HZ | ||
Standby power consumption | 4 W | ||
Earth (ground) fault protection | 30 mA AC, 6 mA DC | ||
Overvoltage category | CAT III | ||
Protection against electric shock | Class I | ||
AC Output specifications | |||
AC output voltage range | |||
3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC | |||
Connection Standart | Type 2 cable
Type 2 socket | ||
Power Cable | |||
Maximum cable diameter | 17.5 mm | ||
Maximum wire cross section | 7.5 mm2 |