Carlo Gavazzi settings

From Teltonika Energy Wiki

Smart energy meters

RS485 parameters for energy meter Carlo Gavazzi series 1; series 2; series 3

Note: Energy meter parameters should match EVSE default parameters.

RS485 parameter EVSE default parameter value (configurable in mobile app)
Modbus adress 1
Baud rate 9600
Parity None
Stop bits 1

Configuring the meter in the mobile application

Note: Users can use two meters with different addresses. Additionally, there will be settings for these energy meters in the installer menu (these settings are the same for both energy meters).


1. Make sure your charger firmware and application are updated to the latest version. (←Release notes: Firmware and iOS / Android).

2. Enter the Installer menu, select Load Balancing, then Modbus RTU.

3. If the charger does not recognize the meter, go to Manual Setup to use a device preset or enter the settings from the RS485 parameters table manually.

Once the meter is successfully configured, press Connect. You will receive a confirmation screen and its status will change to "Connected".

For detailed settings, refer to the energy meter's official documentation.