Main Page > TeltoCharge > General information > Electrical SpecificationsTeltoCharge have different configurations, which can be customizable to suit user needs.
| AC INPUT SPECIFICATIONS | |||
|---|---|---|---|
| 7,4 kW | 11 kW | 22 kW | |
| Input AC power connection | 1 phase | 1 or 3 phases | 1 or 3 phases |
| Maximum current | 32 A | 16 A | 32 A |
| Input voltage | (L-N) 230 ± 10% VAC | 3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC | |
| 1 phase: (L-N) 230 ± 10% VAC | |||
| Rated frequency | 50 / 60 HZ | ||
| Standby power consumption | 4 W | ||
| Earth (ground) fault protection | 30 mA AC, 6 mA DC | ||
| Overvoltage category | CAT III | ||
| Protection against electric shock | Class I | ||
| AC Output specifications | |||
| AC output voltage range | (L-N) 230 ± 10% VAC | 3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC | |
| 1 phase: (L-N) 230 ± 10% VAC | |||
| Connection Standart | Type 2 cable
Type 2 socket | ||
| Power Cable | |||
| Maximum cable diameter | 17.5 mm | ||
| Maximum wire cross section | 7.5 mm2 | ||