EVC2 firmware: Difference between revisions
Appearance
No edit summary |
No edit summary |
||
| Line 2: | Line 2: | ||
===<b><span class="plainlinks">[https://wiki.teltonika-energy.com/images/e/e8/TeltoCharge-v2.1.0.bin EVC2xx V2.1.0]</span></b> | 2025.11.17=== | ===<b><span class="plainlinks">[https://wiki.teltonika-energy.com/images/e/e8/TeltoCharge-v2.1.0.bin EVC2xx V2.1.0]</span></b> | 2025.11.17=== | ||
* <b>New features and settings</b> | * <b>New features and settings</b> | ||
** | ** Support for Shelly PRO 3EM meters added | ||
** EVC2XX potential-free contact support | ** Modbus TCP device control enabled | ||
** Power rotary switch implementation for easier setup | ** New settings: Max group load & Max grid load for DLM/DLB functions | ||
** | ** 2x RS-485 port support | ||
* | *** more information: [[2x RS458 support]] | ||
** EVC2XX potential-free contact support | |||
*** more informationt: [[Potential free contact]] | |||
** Power rotary switch implementation for easier setup | |||
*** more information: [[Power Selector Switch]] | |||
** Automatic grid type detection and phase rotation support | ** Automatic grid type detection and phase rotation support | ||
** LAN-based device control via EV charging app, previously it was possible through Bluetooth only | |||
** LAN-based device control | ** Automatic firmware updates support | ||
** | ** Changed installer menu code to 4 digits | ||
** Changed installer menu code to 4 digits | |||
* <b>Bug Fixes and improvements</b> | * <b>Bug Fixes and improvements</b> | ||
** Various metering and charging bug fixes | ** Various metering and charging bug fixes | ||
Revision as of 11:16, 19 November 2025
Changelog
EVC2xx V2.1.0 | 2025.11.17
- New features and settings
- Support for Shelly PRO 3EM meters added
- Modbus TCP device control enabled
- New settings: Max group load & Max grid load for DLM/DLB functions
- 2x RS-485 port support
- more information: 2x RS458 support
- EVC2XX potential-free contact support
- more informationt: Potential free contact
- Power rotary switch implementation for easier setup
- more information: Power Selector Switch
- Automatic grid type detection and phase rotation support
- LAN-based device control via EV charging app, previously it was possible through Bluetooth only
- Automatic firmware updates support
- Changed installer menu code to 4 digits
- Bug Fixes and improvements
- Various metering and charging bug fixes
- Various Modbus and OCPP communication protocol enhancements
- Charger stability issues resolved
- Bluetooth, NFC and UI features improved
Updating
Use our app to update the station manually
- Use app and go to settings, scroll down and press Device info;
- Press Check for updates;
- At the top, current firmware version can be found.
- User has 2 options: to update from our cloud or by manually uploading a firmware file to the charger.