LED indicators: Difference between revisions
Appearance
mNo edit summary |
mNo edit summary |
||
| Line 34: | Line 34: | ||
|Green LED‘s on – TeltoCharge finished charging, EV is fully charged | |Green LED‘s on – TeltoCharge finished charging, EV is fully charged | ||
|Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D). | |Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D). | ||
|- | |||
| | |||
| | |||
|Open installer menu via Teltonika Energy app, set and save settings. | |||
|Open installer menu via Teltonika Energy app and select to allow simplified charging sequence | |||
| | |||
|Authorize yourself with app or NFC card. | |||
| | |||
| | |||
| | |||
|Open installer menu via Teltonika Energy app and select that charging location is ventilated. To select that charger must be installed in ventilated location. | |||
|} | |} | ||
===RED LED indicators (errors)=== | ===RED LED indicators (errors)=== | ||
{| class="wikitable" | |||
{| class="wikitable | |+ | ||
|A | !A | ||
!B | |||
!C | |||
!D | |||
!E | |||
!F | |||
!G | |||
|- | |- | ||
| | |[[File:TeltoCharge LEDS InputVoltageError.png|center|frameless]] | ||
|[[File:TeltoCharge LEDS OutputVoltageCurrentError.png|center|frameless]] | |||
|[[File:TeltoCharge LEDS CurrentLeakageDetected.png|center|frameless]] | |||
|[[File:TeltoCharge LEDS ConnectivityError.png|center|frameless]] | |||
|[[File:TeltoCharge LEDS TemperatureError.png|center|frameless]] | |||
|[[File:TeltoCharge LEDS OtherErrors.png|center|frameless]] | |||
|[[File:TeltoCharge LEDS FaultyConnection.png|center|frameless]] | |||
|- | |- | ||
| | |Input voltage error | ||
|Output voltage/current error | |||
|Current leakage detected | |||
|Connectivity error | |||
|Temperature error | |||
|Other errors | |||
|Faulty connection to EV | |||
|- | |- | ||
| | |Overvoltage; | ||
| | Undervoltage; | ||
|- | Wrong wiring; | ||
| | |Overvoltage; | ||
Undervoltage; | |||
Current is higher than indicated; | |||
|Current leakage detected | |||
|Cable lock; | |||
PP; | |||
Car diode; | |||
|Temperature reached 80°C | |||
| -12V; | |||
Humidity is too high; | |||
Humidity communication error; | |||
|CP fail | |||
|} | |} | ||
[[Category: Installation]] | [[Category: Installation]] | ||
Revision as of 11:38, 8 June 2022
RED LED indicators (errors)
| A | B | C | D | E | F | G |
|---|---|---|---|---|---|---|
![]() |
![]() |
![]() |
![]() |
|||
| Input voltage error | Output voltage/current error | Current leakage detected | Connectivity error | Temperature error | Other errors | Faulty connection to EV |
| Overvoltage;
Undervoltage; Wrong wiring; |
Overvoltage;
Undervoltage; Current is higher than indicated; |
Current leakage detected | Cable lock;
PP; Car diode; |
Temperature reached 80°C | -12V;
Humidity is too high; Humidity communication error; |
CP fail |