Difference between revisions of "Electrical Specifications"
From Wiki
Line 63: | Line 63: | ||
| colspan="3" |7.5 mm<sup>2</sup> | | colspan="3" |7.5 mm<sup>2</sup> | ||
|} | |} | ||
− | |||
− |
Revision as of 21:38, 30 March 2023
Main Page > TeltoCharge > General information > Electrical SpecificationsTeltoCharge have different configurations, which can be customizable to suit user needs.
AC INPUT SPECIFICATIONS | |||
---|---|---|---|
7,4 kW | 11 kW | 22 kW | |
Input AC power connection | 1 phase | 1 or 3 phases | 1 or 3 phases |
Maximum current | 32 A | 16 A | 32 A |
Input voltage | (L-N) 230 ± 10% VAC | 3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC | |
1 phase: (L-N) 230 ± 10% VAC | |||
Rated frequency | 50 / 60 HZ | ||
Standby power consumption | 4 W | ||
Earth (ground) fault protection | 30 mA AC, 6 mA DC | ||
Overvoltage category | CAT II | ||
Protection against electric shock | Class I | ||
AC Output specifications | |||
AC output voltage range | (L-N) 230 ± 10% VAC | 3 phase: (L-L) 400 ± 10% VAC
(L-N) 230 ± 10% VAC | |
1 phase: (L-N) 230 ± 10% VAC | |||
Connection Standart | Type 2 cable
Type 2 socket | ||
Power Cable | |||
Maximum cable diameter | 17.5 mm | ||
Maximum wire cross section | 7.5 mm2 |