Eastron settings: Difference between revisions
Appearance
m Protected "Eastron settings" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)) |
|||
| Line 1: | Line 1: | ||
==== RS485 parameters for energy meters Eastron SMD54-M ; SMD72D-M V2 ==== | ==== RS485 parameters for energy meters Eastron SMD54-M ; SMD72D-M V2 ==== | ||
''Note: Energy meter parameters should match EVSE default parameters.'' | ''Note 1: Energy meter parameters should match EVSE default parameters.'' <br> | ||
''Note 2: Eastron energy meters booting time is longer than others.'' | |||
{| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;" | {| class="wikitable" style="text-align: center; border: 1px solid #0054A6; font-family: arial, sans-serif; width: 60%;" | ||
Revision as of 12:15, 10 March 2023
RS485 parameters for energy meters Eastron SMD54-M ; SMD72D-M V2
Note 1: Energy meter parameters should match EVSE default parameters.
Note 2: Eastron energy meters booting time is longer than others.
| RS485 parameter | EVSE default parameter value (configurable in mobile app) |
|---|---|
| Modbus adress | 1 |
| Baud rate | 9600 |
| Parity | None |
| Stop bits | 1 |