Difference between revisions of "LED indicators"
Line 195: | Line 195: | ||
|- | |- | ||
− | | colspan="13" |<center><big> | + | | colspan="13" |<center><big>Meaning/What to do</big></center> |
|- | |- | ||
| | | | ||
Line 222: | Line 222: | ||
Unknown device detected. Check if the energy meter is compatible. | Unknown device detected. Check if the energy meter is compatible. | ||
|- | |- | ||
− | | colspan="13" |<center><big>If issues still persists, report it via VIP helpdesk or your sales manager. ('''Note:''' please provide as much information as you can about your issue (photos, videos, etc..) this helps to solve it faster.</big></center> | + | | colspan="13" |<center><big>This LED shows that there is an active warning in the charger. This warning indication will work with other indications. If issues still persists, report it via VIP helpdesk or your sales manager. ('''Note:''' please provide as much information as you can about your issue (photos, videos, etc..) this helps to solve it faster.</big></center> |
|- | |- | ||
|} | |} | ||
[[Category: Installation]] | [[Category: Installation]] |
Revision as of 12:56, 3 January 2023
A | B | C | D | E | F | G | H | I | J | K | L | M |
---|---|---|---|---|---|---|---|---|---|---|---|---|
White LED‘s rolling from the bottom to the top – shows that TeltoCharge is booting up | White pulsing LED‘s – shows that TeltoCharge is in standby mode and waiting for action | Yellow pulsing LED‘s – shows that TeltoCharge is in standby mode with default settings. | Yellow LED‘s on – TeltoCharge is not charging, simplified charging sequence is required. | Blue LED‘s lights up from the middle – TeltoCharge do not require permission, it is waiting for EV to initiate charging process (go to state C). | Blue LED‘s pulsing – permission to charge is not granted. TeltoCharge requires authorization. | Four middle blue LED’s pulsing – TeltoCharge waiting to add new NFC card | Green LED‘s pulsing - Initialisation of charging. | Green LED‘s rolling upwards from the bottom – TeltoCharge is in charging process. | Green LED‘s on – TeltoCharge finished charging. | Purple LED‘s on – TeltoCharge requires ventilation (charging is done in state D). | Red four middle LED's - NFC/RFID card declined from the server. | Green four middle LED's - NFC/RFID card accepted from the server. |
Open installer menu via Teltonika Energy app, set and save settings. | Open installer menu via Teltonika Energy app and select to allow simplified charging sequence | Authorize yourself with app or NFC card. | Open installer menu via Teltonika Energy app and select that charging location is ventilated. To select that charger must be installed in ventilated location. | Check if NFC/RFID card is in a server cards whitelist. |
RED LED indicators (errors)
A | B | C | D | E | F | G |
---|---|---|---|---|---|---|
Input voltage error. | Output voltage/current error. | Current leakage detected. | Connectivity error. | Temperature error. | Internal errors. | Faulty connection to EV. |
Overvoltage;
Undervoltage; Wrong wiring. |
Overvoltage;
Undervoltage; Output current. |
Current leakage detected | Cable lock;
PP fail; Car diode. |
Temperature reached 85°C | -12V; | CP fail |
|
|
|
|
|
|
|
ORANGE LED indicators (warnings)
A | B | C | D | E | F | G | H | I | J | K | L | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Simple CP detected | Temperature warning | Ventilation required | RTC time lost | Simplified CP denied | D state denied | Sensors not calibrated | Energy meter comm error | NFC init error | Low battery voltage | Emeter wrong type | Emeter unidetified | |
Connected EV uses Simplified charging sequence. Charging power is limited to1 Phase 10 A; | Temperature higher than warning limit, current throttling
is present. |
EV requiring ventilation | EVSE date and time lost | Simplified CP detected and not allowed | EV requiring ventilation but charging location is not ventilated | Sensors were not calibrated during HW configuration | Energy meter communication error | NFC initialization error | Low battery voltage EVSE (RTC) | Energy meter configuration mismatch | Energy meter type unidentified | |
Connected EV uses Simplified charging sequence. Charging power is limited. In installer menu option „Simplified charging sequence“ must be turned ON. |
Check if Charging location is sufficiently ventilated |
Check EVSE RTC coin battery (CR 1220) |
Connected EV uses Simplified charging sequence. Simplified CP charging is disabled in Installer menu. |
EV requiring ventilation, but Charging location is specified as not ventilated in Installer menu. |
Contact support. |
Check RS485 connection with external meter. Inspect cable. Check if meter is working. Make sure devices are configutated properly. |
Reboot charger and check if the issue remains. |
Check EVSE RTC coin battery (CR 1220). |
Connected Energy meter and configured Energy meter type in Installer menu are different. |
Unknown device detected. Check if the energy meter is compatible. | ||