Jump to content

Electrical Specifications: Difference between revisions

From Teltonika Energy Wiki
m Protected "Electrical Specifications" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite))
mNo edit summary
Line 12: Line 12:
|Input AC power connection
|Input AC power connection
|1 phase
|1 phase
|3 phases
|1 or 3 phases
|3 phases
|1 or 3 phases
|-
|-
|Input voltage
| rowspan="2" |Input voltage
|22 to 240 VAC
| rowspan="2" |(L-N) 230 ± 10% VAC
|380 to 415 VAC
| colspan="2" |3 phase: (L-L) 400 ± 10% VAC
|380 to 415 VAC
(L-N) 230 ± 10% VAC
|-
| colspan="2" |1 phase: (L-N) 230 ± 10% VAC
|-
|-
|Rated frequency
|Rated frequency
Line 37: Line 39:
! colspan="4" |AC Output specifications
! colspan="4" |AC Output specifications
|-
|-
|AC output voltage range
| rowspan="2" |AC output voltage range
|220 - 240V AC
| rowspan="2" |(L-N) 230 ± 10% VAC
|380 - 415V AC
| colspan="2" |3 phase: (L-L) 400 ± 10% VAC
|380 - 415V AC
(L-N) 230 ± 10% VAC
|-
| colspan="2" |1 phase: (L-N) 230 ± 10% VAC
|-
|-
|Connection Standart
|Connection Standart

Revision as of 16:57, 3 May 2022

Main Page > TeltoCharge > General information > Electrical Specifications

TeltoCharge have different configurations, which can be customizable to suit user needs.


AC INPUT SPECIFICATIONS
7,4 kW 11 kW 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT III
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket