Jump to content

Electrical Specifications: Difference between revisions

From Teltonika Energy Wiki
mNo edit summary
No edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 2: Line 2:




{| class="wikitable" style="text-align: center;"
{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 60%;"
! colspan="4" |AC INPUT SPECIFICATIONS
! colspan="4"; style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |AC INPUT SPECIFICATIONS
|-
|-
|
|
|7,4 kW
|'''EVC10X 7,4 kW'''
|11 kW
|'''EVC11X 11 kW'''
|22 kW
|'''EVC12X 22 kW'''
|-
|-
|Input AC power connection
|Input AC power connection
Line 19: Line 19:
|16 A
|16 A
|32 A
|32 A
|-
|Max power on single phase
|7.4 kW
|3.7 kW
|7.4 kW
|-
|Max power on three phase
|Not applicable
|11 kW
|22 kW
|-
|-
| rowspan="2" |Input voltage
| rowspan="2" |Input voltage
Line 37: Line 47:
|-
|-
|Overvoltage category
|Overvoltage category
| colspan="3" |CAT III
| colspan="3" |CAT II
|-
|-
|Protection against electric shock
|Protection against electric shock
| colspan="3" |Class I
| colspan="3" |Class I
|-
|-
! colspan="4" |AC Output specifications
! colspan="4" style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |AC Output specifications
|-
|-
| rowspan="2" |AC output voltage range
| rowspan="2" |AC output voltage range
Line 55: Line 65:
Type 2 socket
Type 2 socket
|-
|-
! colspan="4" |'''Power Cable'''
! colspan="4" style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" |'''Power Cable'''
|-
|-
|Maximum cable diameter
|Maximum cable diameter
Line 64: Line 74:
|}
|}


[[Category: Technical Data]]
[[Category: General information]]

Latest revision as of 15:59, 3 October 2023

Main Page > TeltoCharge > General information > Electrical Specifications

TeltoCharge have different configurations, which can be customizable to suit user needs.


AC INPUT SPECIFICATIONS
EVC10X 7,4 kW EVC11X 11 kW EVC12X 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Maximum current 32 A 16 A 32 A
Max power on single phase 7.4 kW 3.7 kW 7.4 kW
Max power on three phase Not applicable 11 kW 22 kW
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT II
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

Power Cable
Maximum cable diameter 17.5 mm
Maximum wire cross section 7.5 mm2