| Line 93: | Line 93: | ||
For example: you set 32 A in Installer menu option '''Max power from grid''', so in user menu option '''Load balancing''' you will be able to set limitation from 6 A to 32 A. | For example: you set 32 A in Installer menu option '''Max power from grid''', so in user menu option '''Load balancing''' you will be able to set limitation from 6 A to 32 A. | ||
''By default load balancing is set to 10 A, user can increase this value when | ''By default load balancing is set to 10 A, user can increase this value when they increase Max power from grid option in Installer menu.'' | ||
= Schedule = | = Schedule = | ||
| Line 278: | Line 278: | ||
==Temperature warning== | ==Temperature warning== | ||
There is a possibility to increase temperature warning level. When charger reaches this temperature level, it starts to ventilate itself by decreasing charging power. If Charger reaches | There is a possibility to increase temperature warning level. When charger reaches this temperature level, it starts to ventilate itself by decreasing charging power. If Charger reaches 8''5°C'' it turns off relays and stops charging process. | ||