EVC2 firmware: Difference between revisions
Appearance
No edit summary |
→Changelog: Added - Latest Firmware and Previous Firmware paragraph names |
||
| (One intermediate revision by one other user not shown) | |||
| Line 1: | Line 1: | ||
== | ==Latest Firmware== | ||
===<b><span class="plainlinks">[https://wiki.teltonika-energy.com/images/4/47/TeltoCharge-v2.2.6.bin EVC2xx V2.2.6]</span></b> | 2026.05.01=== | |||
* <b>New features and settings</b> | |||
** Added new solar charging modes for Dynamic Load Management, including Solar Only, ECO, and Hybrid modes. | |||
** Added new Dynamic Load Management capabilities, including [https://wiki.teltonika-energy.com/view/Potential_free_contact potential-free contact support], dynamic IP device discovery and reconnection, and configurable 1-phase charging behavior. | |||
** Expanded Modbus meter support with additional [https://wiki.teltonika-energy.com/view/SDM%20models Eastron] and [https://wiki.teltonika-energy.com/view/A%20and%20B%20models ABB] meter models. | |||
** Added installer setting for IT grid voltage sampling. | |||
** Added an NFC reader cooldown to prevent accidental repeated actions. | |||
* <b>Bug fixes and improvements</b> | |||
** Improved charging session recovery, troubleshooting logs, and reboot reporting after power loss events. | |||
** Improved solar charging and Dynamic Load Management stability, including power limit handling, Modbus TCP communication, ECO mode synchronization, and DLM failsafe behavior. | |||
** Improved communication stability for Bluetooth, LAN, and WebSocket connections. | |||
** Improved charging session energy graph accuracy and HomeWizard P1 meter data handling. | |||
** Improved OCPP configuration request handling and tamper event reporting. | |||
** Improved internal time synchronization. | |||
== Previous Firmwares == | |||
===<b><span class="plainlinks">[https://wiki.teltonika-energy.com/images/3/35/TeltoCharge-v2.1.5.bin EVC2xx V2.1.5]</span></b> | 2026.01.06=== | ===<b><span class="plainlinks">[https://wiki.teltonika-energy.com/images/3/35/TeltoCharge-v2.1.5.bin EVC2xx V2.1.5]</span></b> | 2026.01.06=== | ||
* <b>New features and settings</b> | * <b>New features and settings</b> | ||
Latest revision as of 11:12, 19 May 2026
Latest Firmware
EVC2xx V2.2.6 | 2026.05.01
- New features and settings
- Added new solar charging modes for Dynamic Load Management, including Solar Only, ECO, and Hybrid modes.
- Added new Dynamic Load Management capabilities, including potential-free contact support, dynamic IP device discovery and reconnection, and configurable 1-phase charging behavior.
- Expanded Modbus meter support with additional Eastron and ABB meter models.
- Added installer setting for IT grid voltage sampling.
- Added an NFC reader cooldown to prevent accidental repeated actions.
- Bug fixes and improvements
- Improved charging session recovery, troubleshooting logs, and reboot reporting after power loss events.
- Improved solar charging and Dynamic Load Management stability, including power limit handling, Modbus TCP communication, ECO mode synchronization, and DLM failsafe behavior.
- Improved communication stability for Bluetooth, LAN, and WebSocket connections.
- Improved charging session energy graph accuracy and HomeWizard P1 meter data handling.
- Improved OCPP configuration request handling and tamper event reporting.
- Improved internal time synchronization.
Previous Firmwares
EVC2xx V2.1.5 | 2026.01.06
- New features and settings
- UK product code handling
- Bug fixes and improvements
- NFC scanning module improvements
- Fixed bugs where the settings were not being saved while switching power selector
- Improved OCPP handling when starting/stopping charge
- Various bug fixes related to parameter and information handling
EVC2xx V2.1.0 | 2025.11.24
- New features and settings
- Support for Shelly 3PRO meters added
- more information: Shelly 3PRO configuration
- Modbus TCP device control enabled
- New settings: Max group load & Max grid load for DLM/DLB functions
- 2x RS-485 port support
- more information: 2x RS458 support
- EVC2XX potential-free contact support
- more information: Potential free contact
- Power rotary switch implementation for easier setup
- more information: Power Selector Switch
- Automatic grid type detection and phase rotation support
- LAN-based device control via EV charging app, previously it was possible through Bluetooth only
- Automatic firmware updates support
- Changed installer menu code to 4 digits
- Support for Shelly 3PRO meters added
- Bug fixes and improvements
- Various metering and charging bug fixes
- Various Modbus and OCPP communication protocol enhancements
- Charger stability issues resolved
- Bluetooth, NFC and UI features improved
Updating
Use our app to update the station manually
- Use app and go to settings, scroll down and press Device info;
- Press Check for updates;
- At the top, current firmware version can be found.
- User has 2 options: to update from our cloud or by manually uploading a firmware file to the charger.