Functionalities EVC2: Difference between revisions
Appearance
| (13 intermediate revisions by 3 users not shown) | |||
| Line 6: | Line 6: | ||
# Three phase No neutral | # Three phase No neutral | ||
='''NEW:''' Physical power selector switch= | ='''NEW:''' Physical power selector switch= | ||
* This switch | * This switch is found on the interface board. | ||
* It could turned | * It could be turned to limit MAX device output. By changing rotary switch position it is possible to charge charger’s max output. | ||
* By default (position 0) charger sets max possible output power depending on HW. | * By default (position 0) charger sets max possible output power depending on HW. | ||
* Possible values differ between different modification devices.[[File:Power selector switch.png|thumb|none]] | * Possible values differ between different modification devices.[[File:Power selector switch.png|thumb|none]] | ||
| Line 35: | Line 35: | ||
| Reserved || 9 || N/A || N/A || N/A | | Reserved || 9 || N/A || N/A || N/A | ||
|} | |} | ||
='''NEW:''' IT grid support= | |||
Enable this setting if the charger is installed on an IT grid. <br> | |||
When turned on, the charging station adapts its voltage monitoring for IT grid operation, where voltage can be floating in relation to protective earth (PE). | |||
='''NEW:''' Button switch= | ='''NEW:''' Button switch= | ||
This switch could be found on the interface board, It has 2 features: | This switch could be found on the interface board, It has 2 features: | ||
| Line 120: | Line 125: | ||
If the EV charging process is interrupted (e. g. temporary power outage), the randomized delay will still be in effect when the power is restored, further delaying the start of charging.<br> | If the EV charging process is interrupted (e. g. temporary power outage), the randomized delay will still be in effect when the power is restored, further delaying the start of charging.<br> | ||
The maximum value for Randomized Delay can be set to up to 30 minutes if needed. | |||
= Errors and warnings = | = Errors and warnings = | ||
| Line 243: | Line 248: | ||
==Three phase charging== | ==Three phase charging== | ||
With this slider installer have an ability to turn | With this slider installer have an ability to turn on 3-phase charging (only if 3 phases are connected to the product). | ||
| Line 260: | Line 265: | ||
==Dynamic load balancing== | ==Dynamic load balancing== | ||
This function is used to turn on Dynamic load balancing. To access this feature it is recommended to read more [[Dynamic Load Balancing|here]] | This function is used to turn on Dynamic load balancing. To access this feature it is recommended to read more [[Dynamic Load Balancing EVC2|here]] | ||
''By Default this setting is turned off''<br> | ''By Default this setting is turned off''<br> | ||
== Automatic energy meter type search == | == Automatic energy meter type search == | ||
| Line 289: | Line 294: | ||
„EV Sleep“ feature prevents the charger from repeatedly waking up and restarting when the electric vehicle does not actually begin charging. Some EVs (Electric Vehicles) trigger repeated B2 → D1 → B2 cycles, which can cause unnecessary start attempts. When enabled, this feature protects the charger from entering this loop. | „EV Sleep“ feature prevents the charger from repeatedly waking up and restarting when the electric vehicle does not actually begin charging. Some EVs (Electric Vehicles) trigger repeated B2 → D1 → B2 cycles, which can cause unnecessary start attempts. When enabled, this feature protects the charger from entering this loop. | ||
How the feature works <br> | '''How the feature works''' <br> | ||
When EV Sleep Mode is disabled (Default): <br> | ''When EV Sleep Mode is disabled (Default):'' <br> | ||
The charger behaves normally and does not block the repeated B2/D1 sequence.<br> | The charger behaves normally and does not block the repeated B2/D1 sequence.<br> | ||
If the EV stops charging and then requests the charger again, the EVSE will always try to restart charging.<br> | If the EV stops charging and then requests the charger again, the EVSE will always try to restart charging.<br> | ||
Recommended for users who rely on DLM / Smart Charging and want continuous restart attempts.<br> | Recommended for users who rely on DLM / Smart Charging and want continuous restart attempts.<br> | ||
<br> | <br> | ||
When EV Sleep Mode is enabled:<br> | ''When EV Sleep Mode is enabled:''<br> | ||
The charger starts tracking how many times it enters the sequence:<br> | The charger starts tracking how many times it enters the sequence:<br> | ||
C (charging) → B2 (EV stopped) → D1 (waiting) → B2 → …<br> | C (charging) → B2 (EV stopped) → D1 (waiting) → B2 → …<br> | ||
| Line 305: | Line 310: | ||
The counter resets automatically when the EV successfully starts charging after this sequence. | The counter resets automatically when the EV successfully starts charging after this sequence. | ||
Who should enable this feature? | '''Who should enable this feature?''' <br> | ||
This mode is recommended if: <br> | This mode is recommended if: <br> | ||
1. The user experiences repeated interrupted cycles (stop → wait → start attempt). <br> | 1. The user experiences repeated interrupted cycles (stop → wait → start attempt). <br> | ||