Created page with "← Smart energy meters ==== Phoenix contact smart energy meter technical information ==== {| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 70%;" |- ! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer ! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Type ! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Power supply (V) ! st..."
 
No edit summary
 
Line 1: Line 1:
← [[Smart energy meters]]
<div style="font-family:'Inter','Helvetica Neue',Arial,sans-serif; line-height:1.6;">
==== Phoenix contact smart energy meter technical information ====
 
{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 70%;"
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Phoenix Contact smart energy meter technical information</span> ==
|-
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
{| class="wikitable" style="text-align:center; width:100%;"
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Type
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Energy meter manufacturer
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Power supply (V)
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Type
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for DLB*
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Power supply (V)
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for Solar*
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Supported model for DLB*
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | MID certified
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Supported model for Solar
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | 1/3 phase
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | MID certified
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Connection
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | 1/3 phase
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Direct Connection Rating Value
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Connection
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Datasheet
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Direct Connection Rating Value
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Datasheet
|-
|-
| style="padding: 2px;" rowspan="1" | Phoenix contact
| Phoenix Contact || EEM-MA370-R || 400 V || Yes || Yes || – || 3 phases || CT clamps || NA || [https://www.phoenixcontact.com/en-us/products/energy-meter-eem-ma370-r-2907980 EEM-MA370-R]
| style="padding: 2px;" rowspan="1" | EEM-MA370
| style="padding: 1px;" | 400 V
| style="padding: 2px;" | Yes
| style="padding: 1px;" | Yes
| style="padding: 2px;" | No
| style="padding: 2px;" | 3 phases
| style="padding: 2px;" | Direct
| style="padding: 2px;" | NA
| style="padding: 2px;" | [https://www.phoenixcontact.com/en-us/products/energy-meter-eem-ma370-r-2907980 EEM-MA370]
|}
|}


==== EEM-MA370 meter wiring: ====
'''''*DLB''' - Dynamic load balancing''
[[File:EEMpro meter.png|frameless|630x630px]]
 
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">EEM-MA370-R meter wiring</span> ==
 
[[File:EEMpro meter.png|frameless|alt=Phoenix Contact EEM-MA370-R wiring to the charger|630x630px]]
 
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Powering the energy meter</span> ==
 
To connect the smart energy meter to a power source, follow the manufacturer's installation manual.
 
</div>


====Powering the energy meter====
[[Category:Smart energy meter mastersheet]]
To correctly connect the smart energy meter to a power source, it is recommended to use the manufacturer's installation manuals

Latest revision as of 14:14, 28 October 2026

Main Page > Main Page EVC2 > Smart energy meter mastersheet > EEMpro models

Phoenix Contact smart energy meter technical information

Energy meter manufacturer Type Power supply (V) Supported model for DLB* Supported model for Solar MID certified 1/3 phase Connection Direct Connection Rating Value Datasheet
Phoenix Contact EEM-MA370-R 400 V Yes Yes – 3 phases CT clamps NA EEM-MA370-R

*DLB - Dynamic load balancing

EEM-MA370-R meter wiring

Phoenix Contact EEM-MA370-R wiring to the charger

Powering the energy meter

To connect the smart energy meter to a power source, follow the manufacturer's installation manual.