Jump to content

Chint models: Difference between revisions

From Teltonika Energy Wiki
Created page with "← Smart energy meters ==== Chint smart energy meters technical information ==== {| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family:..."
 
No edit summary
 
(11 intermediate revisions by 3 users not shown)
Line 21: Line 21:
| style="padding: 2px;" | +
| style="padding: 2px;" | +
| style="padding: 2px;" | 3 phases
| style="padding: 2px;" | 3 phases
| style="padding: 2px;" | CT (6 Amps)
| style="padding: 2px;" | Direct
| style="padding: 2px;" | NA
| style="padding: 2px;" | NA
| style="padding: 2px;" | [https://chintglobal.com/products/dtsu666-three-phase-din-rail-meter-8-1007 DTSU 666]
| style="padding: 2px;" | [https://chintglobal.com/products/dtsu666-three-phase-din-rail-meter-8-1007 DTSU 666]
Line 31: Line 31:
| style="padding: 2px;" | +
| style="padding: 2px;" | +
| style="padding: 2px;" | 1 phase
| style="padding: 2px;" | 1 phase
| style="padding: 2px;" | CT (6 Amps)
| style="padding: 2px;" | Direct
| style="padding: 2px;" | NA
| style="padding: 2px;" | NA
| style="padding: 1px;" | [https://chintglobal.com/products/ddsu666-single-phase-din-rail-meter-8-1004 DDSU 666]
| style="padding: 1px;" | [https://chintglobal.com/products/ddsu666-single-phase-din-rail-meter-8-1004 DDSU 666]
|-
|Chint
|DTSU
666-CT
|230V/400V
|Yes
|Yes
| +
|3
phases
|CT
|NA
|[https://store.klinkmann.com/wp-content/uploads/2023/10/manual-DTSSU666.pdf DTSU]
[https://store.klinkmann.com/wp-content/uploads/2023/10/manual-DTSSU666.pdf 666]
|}
|}
<p style="color: red"> '''''TELTOCHARGE SUPPORTS ONLY OEM CHINTS, all of the white labelled CHINTS will not have a communication with TELTOCHARGE ''''' </p>
<p style="color: black"> '''''F.E: CHINT DTSU666-H, DTSU666 SUNGROW are not supported''''' </p>
<p style="color: black"> '''''F.E: CHINT DTSU666-CT, that has "X" on their label is not supported''''' </p>
====Chint meters wiring:====
[[File:Chint_meter_(1).png|alt=|center|frame]]


==== Chint meters wiring: ====
only support OEM Chint  
 
====Powering the energy meter====
 
 
==== Powering the energy meter ====
To correctly connect smart energy meter to power source:
To correctly connect smart energy meter to power source:

Latest revision as of 10:39, 11 April 2025

Smart energy meters

Chint smart energy meters technical information

Energy meter manufacturer Type Power supply (V) Supported model for DLB* Supported model for Solar* MID certified 1/3 phase Connection Direct Connection Rating Value Datasheet
Chint DTSU 666
380 V Yes Yes + 3 phases Direct NA DTSU 666
DDSU 666
230 V Yes Yes + 1 phase Direct NA DDSU 666
Chint DTSU

666-CT

230V/400V Yes Yes + 3

phases

CT NA DTSU

666

TELTOCHARGE SUPPORTS ONLY OEM CHINTS, all of the white labelled CHINTS will not have a communication with TELTOCHARGE

F.E: CHINT DTSU666-H, DTSU666 SUNGROW are not supported

F.E: CHINT DTSU666-CT, that has "X" on their label is not supported

Chint meters wiring:

only support OEM Chint

Powering the energy meter

To correctly connect smart energy meter to power source: