==== Carlo Gavazzi smart energy meters technical information ====
<div style="font-family:'Inter','Helvetica Neue',Arial,sans-serif; line-height:1.6;">


{| class="wikitable" style="text-align: center; border: 1px solid #dddddd; font-family: arial, sans-serif; width: 70%;"
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Carlo Gavazzi smart energy meters technical information</span> ==
 
{| class="wikitable" style="text-align:center; width:100%;"
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Energy meter manufacturer
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Type
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Power supply (V)
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Supported model for DLB*
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Supported model for Solar
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | MID certified
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | 1/3 phase
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Datasheet
|-
| rowspan="10" | Carlo Gavazzi series 1
| rowspan="4" | EM111
| 120 V
| colspan="2" | [https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV7 1 X S1 PF B]
| ✓
| rowspan="10" | 1 phase
| rowspan="4" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/EM111%20DS%20ENG%20170616.pdf EM111]
|-
| 230 V
| colspan="2" | [https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV8 1 X S1 PF B]
| ✓
|-
|-
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
| 120 V
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Type
| colspan="2" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV7 1 X S1 X]
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Power supply (V)
| –
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for DLB*
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for Solar
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | MID certified
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | 1/3 phase
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Datasheet
|-
|-
| style="padding: 2px;" rowspan="6" | Carlo Gavazzi series 1
| 230 V
| style="padding: 2px;" rowspan="4" | EM111 <br>
| colspan="2" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV8 1 X S1 X]
| style="padding: 1px;" | 120 V
| –
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV7 1 X S1 PF A/B]  
|-
| style="padding: 1px;" |
| rowspan="4" | EM112
| style="padding: 1px;" | +
| 120 V
| style="padding: 2px;" rowspan="6" | 1 phase <br>
| colspan="2" | [https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV1 1 X S1 PF B]
| style="padding: 2px;" rowspan="4" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/EM111%20DS%20ENG%20170616.pdf EM111]
| ✓
 
| rowspan="4" | [https://www.gavazzionline.com/pdf/EM112DS.pdf EM112]
|-
|-
| style="padding: 2px;" | 230 V
| 230 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV8 1 X S1 PF A/B]
| colspan="2" | [https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV0 1 X S1 PF B]
| style="padding: 1px;" |
| ✓
| style="padding: 1px;" | +
|-
|-
| style="padding: 2px;" | 120 V
| 120 V
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV7 1 X S1 X]
| colspan="2" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV1 1 X S1 X]
| style="padding: 1px;" |
| –
| style="padding: 1px;" | -
|-
|-
| style="padding: 2px;" | 230 V
| 230 V
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV8 1 X S1 X]
| colspan="2" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV0 1 X S1 X]
| style="padding: 1px;" |
| –
| style="padding: 1px;" | -
|-
|-
| style="padding: 2px;" rowspan="2" | ET112 <br>
| rowspan="2" | ET112
| style="padding: 1px;" | 120 V
| 120 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV1 1 X S1 X]
| [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV1 1 X S1 X]
| style="padding: 1px;" |  
|
| style="padding: 1px;" | -
| –
| style="padding: 2px;" rowspan="2" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/ET112_DS_ENG.PDF ET112]
| rowspan="2" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/ET112_DS_ENG.PDF ET112]
|-
|-
| style="padding: 1px;" | 230 V
| 230 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV0 1 X S1 X]
| [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV0 1 X S1 X]
| style="padding: 1px;" |  
|
| style="padding: 1px;" | -
| –
|-
|-
| style="padding: 2px;" rowspan="7" | Carlo Gavazzi series 3
| rowspan="7" | Carlo Gavazzi series 3
| style="padding: 2px;" rowspan="2"| EM330 <br>
| rowspan="2" | EM330
| style="padding: 1px;" | 400 V
| 400 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/d/dc/20230306131009%21EM330.PNG EM330-DIN AV5 3 H S1 PF A/B]
| [https://wiki.teltonika-energy.com/images/archive/d/dc/20230306131009%21EM330.PNG EM330-DIN AV5 3 H S1 PF A/B]
| style="padding: 1px;" |  
|
| style="padding: 1px;" | +
| ✓
| style="padding: 2px;" rowspan="4" | 3 phase
| rowspan="7" | 3 phase
| style="padding: 2px;" rowspan="2" | [https://www.gavazzionline.com/pdf/EM330.pdf EM330]
| rowspan="2" | [https://www.gavazzionline.com/pdf/EM330.pdf EM330]
|-
|-
| style="padding: 1px;" | 400 V
| 400 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/b/b4/EM330_Standard.PNG EM330-DIN AV5 3 H S1 X]
| [https://wiki.teltonika-energy.com/images/b/b4/EM330_Standard.PNG EM330-DIN AV5 3 H S1 X]
| style="padding: 1px;" |  
|
| style="padding: 1px;" | -
| –
|-
|-
| style="padding: 2px;" rowspan="2" | EM340 <br>
| rowspan="2" | EM340
| style="padding: 1px;" | 400 V
| 400 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 PF A/B]
| colspan="2" | [https://wiki.teltonika-energy.com/images/f/f8/EM340_Solar.PNG EM340-DIN AV2 3 X S1 PFB]
| style="padding: 1px;" |
| ✓
| style="padding: 1px;" | +
| rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340]
| style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340]
|-
|-
| style="padding: 1px;" | 400 V
| 400 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 X]
| colspan="2" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 X]
| style="padding: 1px;" |
| –
| style="padding: 1px;" | -
|-
|-
| style="padding: 2px;" rowspan="2" | ET330 <br>
| rowspan="2" | ET330
| style="padding: 1px;" | 230 V
| 230 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X]
| [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X]
| style="padding: 1px;" |
|
| style="padding: 1px;" | -
| –
| style="padding: 2px;" | 1 phase
| rowspan="2" | [https://www.gavazzionline.com/pdf/ET330_DS_ENG.pdf ET330]
| style="padding: 2px;" rowspan="2" | [https://www.gavazzionline.com/pdf/ET330_DS_ENG.pdf ET330]
|-
|-
 
| 400 V
| style="padding: 1px;" | 400 V
| [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X]
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X]
|
| style="padding: 1px;" |  
| –
| style="padding: 1px;" | -
| style="padding: 2px;" rowspan="2" | 3 phase
|-
|-
| style="padding: 2px;" | ET340
| ET340
| style="padding: 1px;" | 400 V
| 400 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/2/21/ET340.PNG ET340-DIN AV2 3 X S1 X]
| [https://wiki.teltonika-energy.com/images/2/21/ET340.PNG ET340-DIN AV2 3 X S1 X]
| style="padding: 1px;" |  
|
| style="padding: 1px;" | -
| –
| style="padding: 2px;" | [https://www.gavazziautomation.com/docs/pim/DATASHEET/DEU/ET340_DS_DEU.pdf ET340]
| [https://www.gavazziautomation.com/docs/pim/DATASHEET/DEU/ET340_DS_DEU.pdf ET340]
|-
|-
| style="padding: 2px;" rowspan="2" | Carlo Gavazzi series 5
| rowspan="2" | Carlo Gavazzi series 5
| style="padding: 2px;" | EM530 <br>
| EM530
| style="padding: 2px;" | 400 V
| 400 V
| style="padding: 2px;" |
| Yes
| style="padding: 2px;" |
| Yes
| style="padding: 1px;" | +
| ✓
| style="padding: 2px;" rowspan="2" | 3 phase
| rowspan="2" | 3 phase
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM530_DS_ENG.pdf EM530]
| [https://www.gavazzionline.com/pdf/EM530_DS_ENG.pdf EM530]
|-
|-
| style="padding: 2px;" | EM540 <br>
| EM540
| style="padding: 2px;" | 400 V
| 400 V
| style="padding: 2px;" |
| Yes
| style="padding: 2px;" |
| Yes
| style="padding: 1px;" | +
| ✓
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540]
| [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540]
|}
|}


'''''*DLB''' - Dynamic load balancing''
'''''*DLB''' - Dynamic load balancing''


== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Carlo Gavazzi meters wiring:</span> ==


'''Note 1:''' The wire colours are only examples used to tell connection points apart. Communication cables may use different colours, so connect them according to the cable you use.


==== Carlo Gavazzi meters wiring: ====
<div style="border-left:4px solid; padding:4px 16px; margin:16px 0;">
'''Note 2:''' Make sure the power is off before wiring.
</div>


'''Note 1:''' All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory. <br>
=== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Series 1 to charger connection</span> ===
'''Note 2:''' Ensure that the power is off before proceeding with the wiring<br>


[[File:TeltoCharge DLB CarloGavazzi 1phase fixed.png|center|frameless|523x523px]]


===== 1st series to TeltoCharge connection =====
=== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Series 3 and 5 to charger connection</span> ===
[[File:TeltoCharge DLB CarloGavazzi 1phase.png|center|frameless|524x524px]]


===== 3rd and 5th series to TeltoCharge connection =====
[[File:TeltoCharge DLB CarloGavazzi 3phase.png|center|frameless|521x521px]]
[[File:TeltoCharge DLB CarloGavazzi 3phase.png|center|frameless|521x521px]]


==== Powering the energy meter ====
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Powering the energy meter</span> ==
To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.
 
To connect the smart energy meter to a power source, follow the manufacturer's installation manual.


</div>


← [[Smart energy meters]]
[[Category:Smart energy meter mastersheet]]

Latest revision as of 13:05, 28 October 2026

Main Page > Main Page EVC2 > Smart energy meter mastersheet > EM and ET models

Carlo Gavazzi smart energy meters technical information

Energy meter manufacturer Type Power supply (V) Supported model for DLB* Supported model for Solar MID certified 1/3 phase Datasheet
Carlo Gavazzi series 1 EM111 120 V EM111-DIN AV7 1 X S1 PF B ✓ 1 phase EM111
230 V EM111-DIN AV8 1 X S1 PF B ✓
120 V EM111-DIN AV7 1 X S1 X –
230 V EM111-DIN AV8 1 X S1 X –
EM112 120 V EM112-DIN AV1 1 X S1 PF B ✓ EM112
230 V EM112-DIN AV0 1 X S1 PF B ✓
120 V EM112-DIN AV1 1 X S1 X –
230 V EM112-DIN AV0 1 X S1 X –
ET112 120 V ET112-DIN AV1 1 X S1 X – ET112
230 V ET112-DIN AV0 1 X S1 X –
Carlo Gavazzi series 3 EM330 400 V EM330-DIN AV5 3 H S1 PF A/B ✓ 3 phase EM330
400 V EM330-DIN AV5 3 H S1 X –
EM340 400 V EM340-DIN AV2 3 X S1 PFB ✓ EM340
400 V EM340-DIN AV2 3 X S1 X –
ET330 230 V ET330-DIN AV5 3 H S1 X – ET330
400 V ET330-DIN AV5 3 H S1 X –
ET340 400 V ET340-DIN AV2 3 X S1 X – ET340
Carlo Gavazzi series 5 EM530 400 V Yes Yes ✓ 3 phase EM530
EM540 400 V Yes Yes ✓ EM540

*DLB - Dynamic load balancing

Carlo Gavazzi meters wiring:

Note 1: The wire colours are only examples used to tell connection points apart. Communication cables may use different colours, so connect them according to the cable you use.

Note 2: Make sure the power is off before wiring.

Series 1 to charger connection

Series 3 and 5 to charger connection

Powering the energy meter