Difference between revisions of "EM and ET models"

From Wiki
m (Protected "EM and ET models" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
 
(20 intermediate revisions by 2 users not shown)
Line 5: Line 5:
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Energy meter manufacturer
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Type
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Type
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for Dynamic load balancing
+
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Power supply (V)
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for DLB*
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Supported model for Solar
 +
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | MID certified
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | 1/3 phase
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | 1/3 phase
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Datasheet
 
! style="background-color: #0054A6; color:#FFFFFF; padding: 8px;" | Datasheet
 
|-
 
|-
| style="padding: 2px;" rowspan="3" | Carlo Gavazzi series 1
+
| rowspan="10" style="padding: 2px;" | Carlo Gavazzi series 1
| style="padding: 2px;" rowspan="2" | EM111 <br>
+
| style="padding: 2px;" rowspan="4" | EM111 <br>
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/b/b7/20230306130515%21EM111.PNG EM111-DIN AV7/AV8 1 X S1 PF A/B (MID CERTIFIED)]
+
| style="padding: 1px;" | 120 V
| style="padding: 2px;" rowspan="3" | 1 phase <br>
+
| colspan="2" style="padding: 2px;" |[https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV7 1 X S1 PF B]
| style="padding: 2px;" rowspan="2" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/EM111%20DS%20ENG%20170616.pdf EM111]
+
| style="padding: 1px;" | +
 +
| rowspan="10" style="padding: 2px;" | 1 phase <br>
 +
| style="padding: 2px;" rowspan="4" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/EM111%20DS%20ENG%20170616.pdf EM111]
 +
 
 +
|-
 +
| style="padding: 2px;" | 230 V
 +
| colspan="2" style="padding: 1px;" |[https://wiki.teltonika-energy.com/images/7/71/EM111_Solar.PNG EM111-DIN AV8 1 X S1 PF B]
 +
| style="padding: 1px;" | +
 +
|-
 +
| style="padding: 2px;" | 120 V
 +
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV7 1 X S1 X]
 +
| style="padding: 1px;" | -
 +
|-
 +
| style="padding: 2px;" | 230 V
 +
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV8 1 X S1 X]
 +
| style="padding: 1px;" | -
 
|-
 
|-
| style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/d/dc/EM111_Standard.PNG EM111-DIN AV7/AV8 1 X S1 X (NOT MID CERTIFIED)]
+
| rowspan="4" |EM112
 +
|120 V
 +
| colspan="2" style="padding: 2px;" |[https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV1 1 X S1 PF B]
 +
| +
 +
| rowspan="4" style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM112DS.pdf EM112]
 
|-
 
|-
| style="padding: 2px;" | ET112
+
|230 V
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV0/AV1 1 X S1 X (NOT MID CERTIFIED)]
+
| colspan="2" style="padding: 2px;" |[https://wiki.teltonika-energy.com/images/b/b2/EM112_Solar.PNG EM112-DIN AV0 1 X S1 PF B]
| style="padding: 2px;" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/ET112_DS_ENG.PDF ET112]
+
| +
 
|-
 
|-
| style="padding: 2px;" rowspan="6" | Carlo Gavazzi series 3
+
|120 V
 +
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV1 1 X S1 X]
 +
| -
 +
|-
 +
|230 V
 +
| colspan="2" style="padding: 2px;" | [https://wiki.teltonika-energy.com/images/8/81/EM112_Standard.PNG EM112-DIN AV0 1 X S1 X]
 +
| -
 +
|-
 +
| style="padding: 2px;" rowspan="2" | ET112 <br>
 +
| style="padding: 1px;" | 120 V
 +
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV1 1 X S1 X]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | -
 +
| style="padding: 2px;" rowspan="2" | [https://www.gavazziautomation.com/images/PIM/DATASHEET/ENG/ET112_DS_ENG.PDF ET112]
 +
|-
 +
| style="padding: 1px;" | 230 V
 +
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/6/67/ET112.PNG ET112-DIN AV0 1 X S1 X]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | -
 +
|-
 +
| style="padding: 2px;" rowspan="7" | Carlo Gavazzi series 3
 
| style="padding: 2px;" rowspan="2"| EM330 <br>
 
| style="padding: 2px;" rowspan="2"| EM330 <br>
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/d/dc/20230306131009%21EM330.PNG EM330-DIN AV5 3 H S1 PF A/B (MID CERTIFIED)]
+
| style="padding: 1px;" | 400 V
| style="padding: 2px;" rowspan="6" | 3 phase
+
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/d/dc/20230306131009%21EM330.PNG EM330-DIN AV5 3 H S1 PF A/B]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | +
 +
| style="padding: 2px;" rowspan="4" | 3 phase
 
| style="padding: 2px;" rowspan="2" | [https://www.gavazzionline.com/pdf/EM330.pdf EM330]
 
| style="padding: 2px;" rowspan="2" | [https://www.gavazzionline.com/pdf/EM330.pdf EM330]
 
|-
 
|-
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/b/b4/EM330_Standard.PNG EM330-DIN AV5 3 H S1 X (NOT MID CERTIFIED)]
+
| style="padding: 1px;" | 400 V
 +
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/b/b4/EM330_Standard.PNG EM330-DIN AV5 3 H S1 X]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | -
 
|-
 
|-
 
| style="padding: 2px;" rowspan="2" | EM340 <br>
 
| style="padding: 2px;" rowspan="2" | EM340 <br>
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 PF A/B (MID CERTIFIED)]
+
| style="padding: 1px;" | 400 V
 +
| colspan="2" style="padding: 1px;" |[https://wiki.teltonika-energy.com/images/f/f8/EM340_Solar.PNG EM340-DIN AV2 3 X S1 PFB]
 +
| style="padding: 1px;" | +
 
| style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340]
 
| style="padding: 2px;" rowspan="2" | [https://www.gavazzi.no/wp-content/uploads/EM340_DS_ENG.pdf EM340]
 
|-
 
|-
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a9/20230306120205%21EM340_Standard.PNG EM340-DIN AV2 3 X S1 X (NOT MID CERTIFIED)]
+
| style="padding: 1px;" | 400 V
 +
| colspan="2" style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/archive/a/a6/20230306130731%21EM340.PNG EM340-DIN AV2 3 X S1 X]
 +
| style="padding: 1px;" | -
 
|-
 
|-
| style="padding: 2px;" | ET330
+
| style="padding: 2px;" rowspan="2" | ET330 <br>
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X (NOT MID CERTIFIED)]
+
| style="padding: 1px;" | 230 V
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/ET330_DS_ENG.pdf ET330]
+
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | -
 +
| style="padding: 2px;" | 1 phase
 +
| style="padding: 2px;" rowspan="2" | [https://www.gavazzionline.com/pdf/ET330_DS_ENG.pdf ET330]
 +
|-
 +
 
 +
| style="padding: 1px;" | 400 V
 +
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/a/ad/ET330.PNG ET330-DIN AV5 3 H S1 X]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | -
 +
| style="padding: 2px;" rowspan="2" | 3 phase
 
|-
 
|-
 
| style="padding: 2px;" | ET340
 
| style="padding: 2px;" | ET340
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/2/21/ET340.PNG ET340-DIN AV2 3 X S1 X (NOT MID CERTIFIED)]
+
| style="padding: 1px;" | 400 V
 +
| style="padding: 1px;" | [https://wiki.teltonika-energy.com/images/2/21/ET340.PNG ET340-DIN AV2 3 X S1 X]
 +
| style="padding: 1px;" |
 +
| style="padding: 1px;" | -
 
| style="padding: 2px;" | [https://www.gavazziautomation.com/docs/pim/DATASHEET/DEU/ET340_DS_DEU.pdf ET340]
 
| style="padding: 2px;" | [https://www.gavazziautomation.com/docs/pim/DATASHEET/DEU/ET340_DS_DEU.pdf ET340]
 
|-
 
|-
 
| style="padding: 2px;" rowspan="2" | Carlo Gavazzi series 5
 
| style="padding: 2px;" rowspan="2" | Carlo Gavazzi series 5
| style="padding: 2px;" | EM530 <br>
+
| style="padding: 2px;" | EM530  
| style="padding: 2px;" |  
+
| style="padding: 2px;" | 400 V
 +
| style="padding: 2px;" | Yes
 +
| style="padding: 2px;" | Yes
 +
| style="padding: 1px;" | +
 
| style="padding: 2px;" rowspan="2" | 3 phase
 
| style="padding: 2px;" rowspan="2" | 3 phase
 
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM530_DS_ENG.pdf EM530]
 
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM530_DS_ENG.pdf EM530]
 
|-
 
|-
| style="padding: 2px;" | EM540 <br>
+
| style="padding: 2px;" | EM540  
| style="padding: 2px;" |  
+
| style="padding: 2px;" | 400 V
 +
| style="padding: 2px;" | Yes
 +
| style="padding: 2px;" | Yes
 +
| style="padding: 1px;" | +
 
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540]
 
| style="padding: 2px;" | [https://www.gavazzionline.com/pdf/EM540_DS_ENG.pdf EM540]
 +
|}
 +
 +
'''''*DLB''' - Dynamic load balancing''
 +
 +
==== Carlo Gavazzi meters wiring: ====
 +
 +
'''Note 1:''' All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory. <br>
 +
'''Note 2:''' Ensure that the power is off before proceeding with the wiring<br>
 +
 +
 +
===== 1st series to TeltoCharge connection =====
 +
[[File:TeltoCharge DLB CarloGavazzi 1phase.png|center|frameless|524x524px]]
  
|}
+
===== 3rd and 5th series to TeltoCharge connection =====
 +
[[File:TeltoCharge DLB CarloGavazzi 3phase.png|center|frameless|521x521px]]
 +
 
 +
==== Powering the energy meter ====
 +
To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.
 +
 
 +
 
 +
← [[Smart energy meters]]

Latest revision as of 13:12, 5 June 2024

Carlo Gavazzi smart energy meters technical information

Energy meter manufacturer Type Power supply (V) Supported model for DLB* Supported model for Solar MID certified 1/3 phase Datasheet
Carlo Gavazzi series 1 EM111
120 V EM111-DIN AV7 1 X S1 PF B + 1 phase
EM111
230 V EM111-DIN AV8 1 X S1 PF B +
120 V EM111-DIN AV7 1 X S1 X -
230 V EM111-DIN AV8 1 X S1 X -
EM112 120 V EM112-DIN AV1 1 X S1 PF B + EM112
230 V EM112-DIN AV0 1 X S1 PF B +
120 V EM112-DIN AV1 1 X S1 X -
230 V EM112-DIN AV0 1 X S1 X -
ET112
120 V ET112-DIN AV1 1 X S1 X - ET112
230 V ET112-DIN AV0 1 X S1 X -
Carlo Gavazzi series 3 EM330
400 V EM330-DIN AV5 3 H S1 PF A/B + 3 phase EM330
400 V EM330-DIN AV5 3 H S1 X -
EM340
400 V EM340-DIN AV2 3 X S1 PFB + EM340
400 V EM340-DIN AV2 3 X S1 X -
ET330
230 V ET330-DIN AV5 3 H S1 X - 1 phase ET330
400 V ET330-DIN AV5 3 H S1 X - 3 phase
ET340 400 V ET340-DIN AV2 3 X S1 X - ET340
Carlo Gavazzi series 5 EM530 400 V Yes Yes + 3 phase EM530
EM540 400 V Yes Yes + EM540

*DLB - Dynamic load balancing

Carlo Gavazzi meters wiring:

Note 1: All of the Color-coding is strictly exemplary and is used simply to differentiate between different connection points. Different communication cables can have differently coloured wires. Connect them according to used inventory.
Note 2: Ensure that the power is off before proceeding with the wiring


1st series to TeltoCharge connection
TeltoCharge DLB CarloGavazzi 1phase.png
3rd and 5th series to TeltoCharge connection
TeltoCharge DLB CarloGavazzi 3phase.png

Powering the energy meter

To correctly connect smart energy meter to power source, it is recommended to use manufacturers installation manuals.


Smart energy meters