Difference between revisions of "Electrical Specifications"

From Wiki
 
(4 intermediate revisions by 2 users not shown)
Line 6: Line 6:
 
|-
 
|-
 
|
 
|
|'''7,4 kW'''
+
|'''EVC10X 7,4 kW'''
|'''11 kW'''
+
|'''EVC11X 11 kW'''
|'''22 kW'''
+
|'''EVC12X 22 kW'''
 
|-
 
|-
 
|Input AC power connection
 
|Input AC power connection
Line 19: Line 19:
 
|16 A
 
|16 A
 
|32 A
 
|32 A
 +
|-
 +
|Max power on single phase
 +
|7.4 kW
 +
|3.7 kW
 +
|7.4 kW
 +
|-
 +
|Max power on three phase
 +
|Not applicable
 +
|11 kW
 +
|22 kW
 
|-
 
|-
 
| rowspan="2" |Input voltage
 
| rowspan="2" |Input voltage
Line 37: Line 47:
 
|-
 
|-
 
|Overvoltage category
 
|Overvoltage category
| colspan="3" |CAT III
+
| colspan="3" |CAT II
 
|-
 
|-
 
|Protection against electric shock
 
|Protection against electric shock
Line 64: Line 74:
 
|}
 
|}
  
[[Category: Technical Data]]
+
[[Category: General information]]

Latest revision as of 12:59, 3 October 2023

Main Page > TeltoCharge > General information > Electrical Specifications

TeltoCharge have different configurations, which can be customizable to suit user needs.


AC INPUT SPECIFICATIONS
EVC10X 7,4 kW EVC11X 11 kW EVC12X 22 kW
Input AC power connection 1 phase 1 or 3 phases 1 or 3 phases
Maximum current 32 A 16 A 32 A
Max power on single phase 7.4 kW 3.7 kW 7.4 kW
Max power on three phase Not applicable 11 kW 22 kW
Input voltage (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Rated frequency 50 / 60 HZ
Standby power consumption 4 W
Earth (ground) fault protection 30 mA AC, 6 mA DC
Overvoltage category CAT II
Protection against electric shock Class I
AC Output specifications
AC output voltage range (L-N) 230 ± 10% VAC 3 phase: (L-L) 400 ± 10% VAC

(L-N) 230 ± 10% VAC

1 phase: (L-N) 230 ± 10% VAC
Connection Standart Type 2 cable

Type 2 socket

Power Cable
Maximum cable diameter 17.5 mm
Maximum wire cross section 7.5 mm2