Chint models: Difference between revisions
Appearance
No edit summary |
No edit summary |
||
| (7 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
<div style="font-family:'Inter','Helvetica Neue',Arial,sans-serif; line-height:1.6;"> | |||
=== | |||
{| class="wikitable" style="text-align: center; border: | == <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Chint smart energy meters technical information</span> == | ||
{| class="wikitable" style="text-align:center; width:100%;" | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Energy meter manufacturer | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Type | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Power supply (V) | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Supported model for DLB* | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Supported model for Solar | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | MID certified | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | 1/3 phase | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Connection | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Direct Connection Rating Value | |||
! style="background:#001A77; color:#FFFFFF; border-color:#001A77; font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.03em; font-weight:500; padding:8px;" | Datasheet | |||
|- | |- | ||
| rowspan="3" | Chint | |||
| DTSU 666 || 380 V || Yes || Yes || ✓ || 3 phases || Direct || NA || [https://chintglobal.com/products/dtsu666-three-phase-din-rail-meter-8-1007 DTSU 666] | |||
|- | |- | ||
| | | DDSU 666 || 230 V || Yes || Yes || ✓ || 1 phase || Direct || NA || [https://chintglobal.com/products/ddsu666-single-phase-din-rail-meter-8-1004 DDSU 666] | ||
| | |||
| | |||
| | |||
| | |||
| | |||
| | |||
| | |||
| | |||
|- | |- | ||
| | | DTSU666-CT || 230 V / 400 V || Yes || Yes || ✓ || 3 phases || CT clamps || NA || [https://store.klinkmann.com/wp-content/uploads/2023/10/manual-DTSSU666.pdf DTSU666-CT] | ||
|} | |||
| | |||
| | '''''*DLB''' - Dynamic load balancing'' | ||
| | |||
| | <div style="border-left:4px solid; padding:4px 16px; margin:16px 0;"> | ||
| | '''Note:''' The charger supports only OEM Chint meters. White-labelled Chint meters cannot communicate with the charger. For example, the CHINT DTSU666-H and the DTSU666 SUNGROW are not supported, nor is a CHINT DTSU666-CT with an "X" on its label. | ||
| | </div> | ||
| | |||
== <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Chint meters wiring</span> == | |||
|[https://store.klinkmann.com/wp-content/uploads/2023/10/manual-DTSSU666.pdf | |||
| | [[File:Chint_meter_(1).png|alt=Chint meter wiring to the charger|center|frame]] | ||
=== | == <span style="font-family:'Oswald','Arial Narrow',sans-serif; text-transform:uppercase; letter-spacing:0.02em;">Powering the energy meter</span> == | ||
To connect the smart energy meter to a power source, follow the manufacturer's installation manual. | |||
</div> | |||
[[Category:Smart energy meter mastersheet]] | |||
Latest revision as of 14:06, 28 October 2026
Main Page > Main Page EVC2 > Smart energy meter mastersheet > Chint modelsChint smart energy meters technical information
| Energy meter manufacturer | Type | Power supply (V) | Supported model for DLB* | Supported model for Solar | MID certified | 1/3 phase | Connection | Direct Connection Rating Value | Datasheet |
|---|---|---|---|---|---|---|---|---|---|
| Chint | DTSU 666 | 380 V | Yes | Yes | ✓ | 3 phases | Direct | NA | DTSU 666 |
| DDSU 666 | 230 V | Yes | Yes | ✓ | 1 phase | Direct | NA | DDSU 666 | |
| DTSU666-CT | 230 V / 400 V | Yes | Yes | ✓ | 3 phases | CT clamps | NA | DTSU666-CT |
*DLB - Dynamic load balancing
Note: The charger supports only OEM Chint meters. White-labelled Chint meters cannot communicate with the charger. For example, the CHINT DTSU666-H and the DTSU666 SUNGROW are not supported, nor is a CHINT DTSU666-CT with an "X" on its label.
Chint meters wiring

Powering the energy meter
To connect the smart energy meter to a power source, follow the manufacturer's installation manual.